Abstract

Objective: Limited visibility of post-resection muscle-invasive bladder cancer (MIBC) on CT hinders radiotherapy dose escalation of the residual tumour. Diffusion-weighted MRI (DW-MRI) visualises areas of high tumour burden and is increasingly used within diagnosis and as a biomarker for cancer. DW-MRI could, therefore, facilitate dose escalation, potentially via dose-painting and/or accommodating response. However, the distortion inherent in DW-MRI could limit geometric accuracy. Therefore, this study aims to quantify DW-MRI distortion via imaging of a bladder phantom. Methods: A phantom was designed to mimic MIBC and imaged using CT, DW-MRI and T2W-MRI. Fiducial marker locations were compared across modalities and publicly available software was assessed for correction of magnetic susceptibility-related distortion. Results: Fiducial marker locations on CT and T2W-MRI agreed within 1.2 mm at 3 T and 1.8 mm at 1.5 T. The greatest discrepancy between CT and apparent diffusion coefficient (ADC) maps was 6.3 mm at 3 T, reducing to 1.8 mm when corrected for distortion. At 1.5 T, these values were 3.9 mm and 1.7 mm, respectively. Conclusions: Geometric distortion in DW-MRI of a model bladder was initially >6 mm at 3 T and >3 mm at 1.5 T; however, established correction methods reduced this to <2 mm in both cases. Advances in knowledge: A phantom designed to mimic MIBC has been produced and used to show distortion in DW-MRI can be sufficiently mitigated for incorporation into the radiotherapy pathway. Further investigation is therefore warranted to enable individually adaptive image-guided radiotherapy of MIBC based upon DW-MRI.

Publisher

British Institute of Radiology

Subject

Radiology Nuclear Medicine and imaging,General Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3