Inter-fraction robustness of intensity-modulated proton therapy in the post-operative treatment of oropharyngeal and oral cavity squamous cell carcinomas

Author:

Hague Christina12,Aznar Marianne34,Dong Lei5,Fotouhi-Ghiam Alireza5,Lee Lip Wai1,Li Taoran5,Lin Alexander5,Lowe Matthew6,Lukens John N5,McPartlin Andrew1,O'Reilly Shannon5,Slevin Nick12,Swisher-Mcclure Samuel5,Thomson David12,Van Herk Marcel78,West Catharine910,Zou Wei5,Teo Boon-Keng Kevin5

Affiliation:

1. Department of Clinical Oncology, The Christie NHS Foundation Trust, Manchester, UK

2. University of Manchester, Manchester Academic Health Sciences Centre, Manchester, UK

3. Manchester Cancer Research Centre, Division of Molecularand Clinical Cancer Science, School of Medical Sciences, Faculty of Biology, Medicine and Health, University of Manchester, Manchester Academic HealthSciences Centre, Manchester, UK

4. The Christie NHS Foundation Trust, Manchester Academic Health Sciences Centre, Manchester, UK

5. Department of Radiation Oncology, University of Pennsylvania, Philadelphia, USA

6. Christie Medical Physics and Engineering, The Christie NHS Foundation Trust, Manchester, UK

7. Division Clinical Cancer Science, School of Medical Sciences, Faculty of Biology, Medicine and Health, University of Manchester, Manchester Academic Health Science Centre, Manchester, UK

8. Department of Radiotherapy Related Research, The Christie NHS Foundation Trust, Manchester, UK

9. Translational Radiobiology Group, Division of Cancer Sciences, Manchester Academic Health Science Centre, University of Manchester, Manchester, UK

10. The Christie NHS Foundation Trust, Manchester, UK

Abstract

Objective: To evaluate dosimetric consequences of inter-fraction setup variation and anatomical changes in patients receiving multifield optimised (MFO) intensity modulated proton therapy for post-operative oropharyngeal (OPC) and oral cavity (OCC) cancers. Methods: Six patients receiving MFO for post-operative OPC and OCC were evaluated. Plans were robustly optimised to clinical target volumes (CTVs) using 3 mm setup and 3.5% range uncertainty. Weekly online cone beam CT (CBCT) were performed. Planning CT was deformed to the CBCT to create virtual CTs (vCTs) on which the planned dose was recalculated. vCT plan robustness was evaluated using a setup uncertainty of 1.5 mm and range uncertainty of 3.5%. Target coverage, D95%, and hotspots, D0.03cc, were evaluated for each uncertainty along with the vCT-calculated nominal plan. Mean dose to organs at risk (OARs) for the vCT-calculated nominal plan and relative % change in weight from baseline were evaluated. Results: Robustly optimised plans in post-operative OPC and OCC patients are robust against inter-fraction setup variations and range uncertainty. D0.03cc in the vCT-calculated nominal plans were clinically acceptable across all plans. Across all patients D95% in the vCT-calculated nominal treatment plan was at least 100% of the prescribed dose. No patients lost ≥10% weight from baseline. Mean dose to the OARs and max dose to the spinal cord remained within tolerance. Conclusion: MFO plans in post-operative OPC and OCC patients are robust to inter-fraction uncertainties in setup and range when evaluated over multiple CT scans without compromising OAR mean dose. Advances in knowledge: This is the first paper to evaluate inter-fraction MFO plan robustness in post-operative head and neck treatment.

Publisher

British Institute of Radiology

Subject

Radiology, Nuclear Medicine and imaging,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3