CT-pathologic correlation of non-calcified atherosclerotic arterial plaques: a study using carotid endarterectomy specimens

Author:

Higashi Masahiro12,Yamada Naoaki2,Imakita Satoshi3,Yutani Chikao45,Ishibashi-Ueda Hatsue6,Iihara Koji7,Naito Hiroaki8

Affiliation:

1. Department of Radiology, National Hospital Organization Osaka National Hospital, Osaka, Japan

2. Department of Radiology, National Cerebral and Cardiovascular Center, Suita, Japan

3. Hi-Medic Clinic, Osaka, Japan

4. Department of Pathology, Amagasaki Central Hospital, Amagasaki, Japan

5. Department of Pathology, Cardiovascular Center Osaka Gyoumeikan Hospital, Osaka, Japan

6. Department of Pathology, National Cerebral and Cardiovascular Center, Suita, Japan

7. Department of Neurosurgery, Graduate School of Medical Science Kyushu University, Fukuoka, Japan

8. Department of Radiology, Nippon Life Hospital, Osaka, Japan

Abstract

Objective: Pathologic features of atherosclerotic plaques on CT are not established. We compared CT values among pathologically confirmed plaque constituents and evaluated their ability to distinguish plaque constituents. Methods: 50 histopathological images of carotid endarterectomy samples from 10 males and 2 females (age 54–74 years, average 65.9 years) were examined. We compared pre-operative CT [pre-contrast (CT-P), early post-contrast phase (CT-E), delayed post-contrast phase (CT-D)] of lipid-rich necrotic core (NC) and fibrous tissue (F) plaque components with pathological images. The ability of features to differentiate plaque components using several discrimination techniques were compared. Results: CT values of NC and F were 36 ± 13, 45 ± 11 (mean ± standard deviation, Hounsfield unit, HU), 41 ± 17, 69 ± 18, and 44 ± 16, 70 ± 13 in CT-P (p < 0.01), CT-E (p < 0.0001), and CT-D (p < 0.0001), respectively. The threshold, sensitivity, and accuracy for distinguishing NC from F were 44 HU, 74%, and 68%; 55 HU, 85%, and 85%; and 63 HU, 92%, and 84% in CTP, CT-E, and CT-D, respectively. CT-P had lower accuracy than CT-E and CT-D (both p < 0.05), but CT-E and CT-D were similar. CT-E and CT-D yielded 90 and 91% sensitivity and accuracy, respectively in linear discrimination analysis. Conclusion: In both pre- and post-contrast CT, CT values were lower in NC than F. Although values overlapped, using two-phase post-contrast CTs improved discrimination ability. Advances in knowledge: Our findings may help to establish computer-aided diagnosis of vulnerable atherosclerotic plaques in future.

Publisher

British Institute of Radiology

Subject

Radiology Nuclear Medicine and imaging,General Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3