Feasibility of MRI based extracellular volume fraction and partition coefficient measurements in thigh muscle

Author:

Goodall Alex F12ORCID,Broadbent David A1,Dumitru Raluca B34,Buckley David L5,Tan Ai Lyn34,Buch Maya H346,Biglands John D13

Affiliation:

1. Department Of Medical Physics and Engineering, Leeds Teaching Hospitals NHS Trust, Leeds, UK

2. Department of Medical Imaging and Medical Physics, Sheffield Teaching Hospitals Foundation Trust, Sheffield, UK

3. NIHR Leeds Biomedical Research Centre, Leeds, UK

4. Leeds Institute of Rheumatic and Musculoskeletal Medicine, University Of Leeds, Leeds, UK

5. Biomedical Imaging, University Of Leeds, Leeds, UK

6. Centre for Musculoskeletal Research, School of Biological Sciences, Faculty of Biology, Medicine & Health, University of Manchester, Manchester, UK

Abstract

Objective: This study aimed to assess the feasibility of extracellular volume-fraction (ECV) measurement, and time to achieve contrast equilibrium (CE), in healthy muscles, and to determine whether in-flow and partial-volume errors in the femoral artery affect measurements, and if there are differences in the partition coefficient (λ) between muscles. Methods: T1 was measured in the biceps femoris, vastus intermedius, femoral artery and aorta of 10 healthy participants. This was repeated alternately between the thigh and aorta for ≥25 min following a bolus of gadoterate meglumine. λ was calculated for each muscle/blood measurement. Time to CE was assessed semi-quantitatively. Results: 8/10 participants achieved CE. Time to CE = 19±2 min (mean ± 95% confidence interval). Measured λ: biceps femoris/aorta = 0.210±0.034, vastus intermedius/aorta = 0.165±0.015, biceps femoris/femoral artery = 0.265±0.054, vastus intermedius/femoral artery = 0.211±0.026. There were significant differences in λ between the muscles when using the same vessel (p < 0.05), and between λ calculated in the same muscle when using different vessels (p < 0.05). Conclusion: ECV measurements in the thigh are clinically feasible. The use of the femoral artery for the blood measurement is associated with small but significant differences in λ. ECV measurements are sensitive to differences between muscles within the healthy thigh. Advances in knowledge: This paper determines the time to contrast equilibrium in the healthy thigh and describes a method for measuring accurately ECV in skeletal muscle. This can aid in the diagnosis and understanding of inflammatory auto-immune diseases.

Publisher

British Institute of Radiology

Subject

Radiology, Nuclear Medicine and imaging,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3