Evaluation of the liver with virtual non-contrast: single institution study in 149 patients undergoing TAVR planning

Author:

Laukamp Kai Roman123ORCID,Lennartz Simon3,Ho Vivian12,Große Hokamp Nils123,Zopfs David3,Gupta Amit12,Graner Frank Philipp12,Borggrefe Jan3,Gilkeson Robert12,Ramaiya Nikhil12

Affiliation:

1. Department of Radiology, University Hospitals Cleveland Medical Center, Cleveland, OH, USA

2. Department of Radiology, Case Western Reserve University, Cleveland, OH, USA

3. Institute for Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany

Abstract

Objective: To evaluate accuracy of virtual-non-contrast images (VNC) compared to true-unenhanced-images (TNC) for evaluation of liver attenuation acquired using spectral-detector CT (SDCT). Methods: 149 patients who underwent multiphase transcatheter-aortic-valve-replacement (TAVR) SDCT-examinations [unenhanced-chest (TNC), CT-angiography chest (CTA-chest, early arterial-phase) and abdomen (CTA-abdomen, additional early arterial-phase after a second injection of contrast media)] were retrospectively included. VNC of CTA-chest (VNC-chest) and CTA-abdomen (VNC-abdomen) were reconstructed and compared to TNC. Region of interest-based measurement of mean attenuation (Hounsfield unit, HU) was applied in the following regions: liver, spleen, abdominal aorta and paraspinal muscle. Results: VNC accuracy was high in the liver, spleen, abdominal aorta and muscle for abdomen-scanning. For the liver, average attenuation was 59.0 ± 9.1 HU for TNC and 72.6 ± 9.5 HU for CTA-abdomen. Liver attenuation in VNC-abdomen (59.1 ± 6.4 HU) was not significantly different from attenuation in TNC (p > 0.05). In contrast, VNC was less accurate for chest-scanning: Due to the protocol, in CTA-chest no contrast media was present in the liver parenchyma as indicated by the same attenuation in TNC (59.0 ± 9.1 HU) and CTA-chest (58.8 ± 8.9 HU, p > 0.05). Liver attenuation in VNC-chest (56.2 ± 6.4 HU, p < 0.05) was, however, significantly lower than in TNC and CTA-chest implying an artificial reduction of attenuation. Conclusion: VNC performed well in a large cohort of TAVR-examinations yielding equivalent mean attenuations to TNC; however, application of this technique might be limited when no or very little contrast media is present in parenchyma, more precisely in an early arterial-phase of the liver. Advances in knowledge: This study showed that VNC can be reliably applied in cardiac protocols when certain limitations are considered

Publisher

British Institute of Radiology

Subject

Radiology, Nuclear Medicine and imaging,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3