Assessment of robustness against setup uncertainties using probabilistic scenarios in lung cancer: a comparison of proton with photon therapy

Author:

Teoh Suliana12ORCID,George Ben12,Fiorini Francesca13,Vallis Katherine A12,Van den Heuvel Frank12

Affiliation:

1. CRUK and MRC Oxford Institute for Radiation Oncology, Old Road Campus Research Building, Off Roosevelt Drive, University of Oxford, Oxford, OX3 7DQ, UK

2. Department of Radiotherapy, Oxford Cancer Centre, Oxford University Hospitals NHS Foundation Trust, Oxford OX3 7LE, UK

3. Rutherford Cancer Centre Thames Valley, 3 Collegiate Square, Shinfield, Reading RG2 9LH, UK

Abstract

Objective: We compared the sensitivity of intensity modulated proton therapy (IMPT) and photon volumetric modulated arc therapy (VMAT) plans to setup uncertainties in locally advanced non-small cell lung cancer (NSCLC) using probabilistic scenarios. Methods: Minimax robust (MM) and planning target volume (PTV) optimised IMPT and VMAT nominal plans were created with physical dose of 70 Gy in 35 fractions in 10 representative patients. Using population data of setup errors, a fractionated treatment course was simulated, summed (Dsum) and compared to the nominal plan. Three treatment-course simulations were done for each plan. Target robustness criteria were: dose deviation of ≤5% to clinical target volume (CTV) D98% and CTV V95% ≥ 99.9%. Voxelwise simulation repeatability was analysed using Bland–Altman plots. Acceptable limits of agreement were 2% of the prescription dose. Results: All Dsum met target robustness criteria. While fraction VMAT and MM-IMPT doses were excellent, simulated fraction doses in PTV-IMPT were suboptimal. Almost all (>99%) of VMAT and MM-IMPT fraction doses met both target robustness criteria. For PTV-IMPT, only 96.9 and 80.3% of fractions met CTVD98% and V95% criteria respectively. Simulation repeatability was excellent (limits of agreement range: 0.41–1.1 Gy) with strong positive correlations. Conclusion: When considering the whole treatment course, setup errors do not influence robustness irrespective of planning techniques used. However, on a fraction level, VMAT and MM-IMPT plans are superior compared to PTV-IMPT plans. Advances in knowledge: Probabilistic analysis provides a fast and practical method for evaluating VMAT and IMPT plan sensitivity against setup uncertainty. VMAT and robust-optimised IMPT plans have comparable sensitivity to setup uncertainties in conventionally fractionated treatment for NSCLC.

Publisher

British Institute of Radiology

Subject

Radiology Nuclear Medicine and imaging,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3