Diagnostic reference levels and achievable doses for common computed tomography examinations: Results from the Japanese nationwide dose survey

Author:

Matsunaga Yuta12,Chida Koichi2,Kondo Yuya3,Kobayashi Kenichi4,Kobayashi Masanao5,Minami Kazuyuki5,Suzuki Shoichi5,Asada Yasuki5

Affiliation:

1. Department of Imaging, Nagoya Kyoritsu Hospital, Nagoya, Japan

2. Department of Radiological Technology, Faculty of Health Sciences, Tohoku University Graduate School of Medicine, Sendai, Japan

3. Graduate school of Health Sciences, Fujita Health University, Toyoake, Japan

4. Department of Radiology, Fujita Health University Hospital, Toyoake, Japan

5. Faculty of Radiological Technology, School of Health Science, Fujita Health University, Toyoake, Japan

Abstract

Objective: To propose a new set of Japanese diagnostic reference levels (DRLs) and achievable doses (ADs) for 2017 and to verify the usefulness of Japanese DRLs (DRLs 2015) for CT, by investigating changes in the volume CT dose index (CTDIvol) from 2014 to 2017. Methods: Detailed information on the CT scan parameters used throughout Japan were obtained by questionnaire survey. The CTDIvol and dose-length product for the 11 commonest adult and 6 commonest paediatric CT examinations were surveyed and compared with 2014 data and DRLs 2015. Results: Evaluations of adult head (helical), and abdomen and pelvis without contrast agent, paediatric chest without contrast agent, and abdomen and pelvis without contrast agent showed a slightly lower mean CTDIvol in 2017 than in 2014 (t-test, p < 0.05). The interquartile range of CTDIvol for all 2017 examinations was lower than in 2014. Conclusions: This study verified the lower mean, 75th percentile, and interquartile range by investigating changes in the CTDIvol from 2014 to 2017. The DRLs 2015 contributed to CT radiation dose reduction. Advances in knowledge: The widespread implementation of iterative reconstruction algorithms and low-tube voltage in CT scanners is likely to facilitate further reduction in the CT radiation dose used in Japan. Although radiological technologists may require further education on appropriate CTDIvol and DLP usage, the DRLs 2015 greatly contributed to the reduction of the CT radiation dose used in Japan.

Publisher

British Institute of Radiology

Subject

Radiology, Nuclear Medicine and imaging,General Medicine

Cited by 43 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献