The associated factors for radiation dose variation in cardiac CT angiography

Author:

Alhailiy Ali B12ORCID,Ekpo Ernest U1,Kench Peter L1,Ryan Elaine A1,Brennan Patrick C1,McEntee Mark1

Affiliation:

1. The University of Sydney, Faculty of Health Sciences, Discipline of Medical Radiation Science, Sydney, NSW, Australia

2. Prince Sattam Bin Abdulaziz University, Al-Kharj, Kingdom of Saudi Arabia

Abstract

Objective: This study aimed to examine the associated factors for dose variation and influence cardiac CT angiography (CCTA) dose benchmarks in current CT imaging centres. Methods: A questionnaire was distributed to CT centres across Australia and Saudi Arabia. All participating centres collected data for adults who underwent a CCTA procedure. The questionnaire gathered information about the examination protocol, scanning parameters, patient parameters, and volume CT dose index (CTDI vol) and dose–length product (DLP). A stepwise regression analysis was performed to assess the contribution of tube voltage (kV), padding time technique, cross-sectional area (CSA) of chest and weight to DLP. Results: A total of 17 CT centres provided data for 423 CCTA examinations. The median CTDIvol, DLP and effective dose were 18 mGy, 256 mGy.cm and 5.2 mSv respectively. There was a statistically significant difference in DLP between retrospective and prospective ECG-gating modes (p = 0.001). Median DLP from CCTA using padding technique was 61% higher than CCTA without padding (p = 0.001). The stepwise regression showed that kV was the most significant predictor of DLP followed by padding technique then CSA while patient weight did not statistically significantly predict DLP. Correlation analysis showed a strong positive correlation between weight and CSA (r = 0.78), and there was a moderate positive correlation between weight and DLP (r = 0.42), as well as CSA and DLP (r = 0.48). Conclusion: Findings show radiation dose variations for CCTA. The associated factors for dose variation found in this study are scanning mode, kV, padding time technique and CSA of the chest. This results support the need to include CSA measurements in future dose survey and for setting DRLs. Advances in knowledge: The study provides baseline information that helps to understand the associated factors for dose variations and high doses within and between centres performing CCTA.

Publisher

British Institute of Radiology

Subject

Radiology, Nuclear Medicine and imaging,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3