A comparative study on image quality of two digital intraoral sensors

Author:

Aziman Cinar1,Hellén-Halme Kristina2,Shi Xie-Qi13

Affiliation:

1. Section of Oral Diagnostics and Surgery, Department of Dental Medicine, Karolinska Institutet, Huddinge, Sweden

2. Department of Oral and Maxillofacial Radiology, Faculty of Odontology, Malmö University, Malmö, Sweden

3. Section of Oral Maxillofacial Radiology, Department of Clinical Dentistry, University of Bergen, Bergen, Norway

Abstract

Objectives The aims of this study were to evaluate the subjective image quality and reliability of two digital sensors. In addition, the image quality of the two sensors evaluated by specialists and general dentists were compared. Methods: 30 intraoral bitewings from five patients were included in the study, 15 were exposed with a Dixi sensor (CCD-based) and 15 with a ProSensor (CMOS-based) using modified parallel technique. Three radiologists and three general dentists evaluated the images in pair. A five-point scale was used to register the image quality. Visual grading characteristics (VGC) analysis was performed to compare the image quality and the observer agreement was assessed in terms of intra class correlation co-efficient. Results No statistically significant difference was found on image quality between the sensors. The average scores of the observer agreement were moderate with an average of 0.66 and an interval of 0.30 to 0.87, suggesting that there was a large variation on preference of image quality. However, there was a statistically significant difference in terms of the area under the VGC- curves between the specialist group and the general dentist group ( p = 0.043), in which the specialist group tended to favor the ProSensor. Conclusions Subjective image quality of the two intraoral sensors were comparable when evaluated by both general and oral radiologists. However, the radiologists seemed to prefer the ProSensor to the Dixi as compared to general dentists. Inter- observer conformance showed a large variation on the preference of the image quality.

Publisher

British Institute of Radiology

Subject

General Dentistry,Radiology, Nuclear Medicine and imaging,General Medicine,Otorhinolaryngology

Cited by 9 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3