Quantitative evaluation of artefact reduction from metallic dental materials in short tau inversion recovery imaging: efficacy of syngo WARP at 3.0 tesla

Author:

Tran Lan Thi Xuan1,Sakamoto Junichiro1,Kuribayashi Ami1,Watanabe Hiroshi1,Tomisato Hiroshi2,Kurabayashi Tohru1

Affiliation:

1. Oral and Maxillofacial Radiology, Graduate School, Tokyo Medical and Dental University (TMDU), Tokyo, Japan

2. Oral and Maxillofacial Radiology Clinic, Dental Hospital, Tokyo Medical and Dental University (TMDU), Tokyo, Japan

Abstract

Objectives: To evaluate the effects of syngo WARP on reducing metal artefacts from dental materials. Methods: Short tau inversion recovery (STIR) with syngo WARP [a dedicated metal artefact reduction sequence in combination with view-angle-tilting (VAT)] was performed using phantoms of three dental alloys: cobalt–chromium (Co–Cr), nickel–chromium (Ni–Cr), and titanium (Ti). Artefact volumes and reduction ratios of black, white and overall artefacts in the standard STIR and syngo WARP images with several different parameter settings were quantified according to standards of the American Society for Testing and Materials F2119-07. In all sequences, the artefact volumes and reduction ratios were compared. The modulation transfer function (MTF) and contrast-to-noise ratio (CNR) were also measured for evaluation of image quality. Results: In standard STIR, the overall artefact volume of Co–Cr was markedly larger than those of Ni–Cr and Ti. All types of artefacts tended to be reduced with increasing receiver bandwidth (rBW) and VAT. The effect of artefact reduction tended to be more obvious in the axial plane than in the sagittal plane. Compared with standard STIR, syngo WARP with a matrix of 384 × 384, receiver bandwidth of 620 Hz/pixel, and VAT of 100 % in the axial plane obtained reduction effects of 30 % (white artefacts), 45 % (black artefacts), and 38 % (overall artefacts) although MTF and CNR decreased by 30 and 22 % compared with those of standard STIR, respectively. Conclusions: syngo WARP for STIR can effectively reduce metal artefacts from dental materials.

Publisher

British Institute of Radiology

Subject

General Dentistry,Radiology Nuclear Medicine and imaging,General Medicine,Otorhinolaryngology

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3