Investigation of the Effect of Ultrasonic Inspection Probe Diameters on Impact Echo Value

Author:

GÖRGÜN Emre1

Affiliation:

1. CUMHURİYET ÜNİVERSİTESİ

Abstract

The aim of this study is to investigate the relationship between the pulse echo value of the probes used in the ultrasonic examination method. Ultrasonic inspection method is known as one of the non-destructive inspection methods. Thanks to this method, discontinuities in the material can be detected without damaging the material to be examined. It works with the principle of sending the sound waves produced by piezoelectric materials to the material surface and reading the sound waves coming reversibly. As the general working principle, sound frequencies are used in the ranges that the human ear cannot hear. These frequency values vary according to the structure of the material and the environment to be examined, but generally vary between 1MHz and 4MHz. In our study, train wheels were preferred as material. Train wheels are produced from medium carbon steel material by forging method. Inspections of train wheels, which are exposed to dynamic stresses during operation, are of great importance. The method of drilling holes on the train wheels with 3mm artificial errors were created. Inspection was carried out with total probes with 3 different diameters and 3 different frequency values on the train wheels on which artificial defects were found. A spring mechanism has been prepared for the probes to contact the material surface with the same pressure force. Experimental groups and a data set was created of 9 tests were carried out with 6 different. The sound waves given from the probes were recorded as db unit. Although the frequency of the probes is seen as the basic parameter in the selection of probes in the literature, it has been observed that different probe diameters have an effect on the inspection sensitivity. IBk algorithm was used to determine the relationship between probe diameters and incoming sound waves. This algorithm is based on the principle of classifying objects based on the closest training examples in the feature space. In the model made using the IBk algorithm, a high correlation of 89% was found in the probe diameter and pulse echo value. This value is important in terms of showing the relationship between the probe diameters, which cannot be considered as the main parameter, and the pulse echo value.

Publisher

Karadeniz Fen Bilimleri Dergisi

Subject

Community and Home Care

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3