Quartz Crystal Microbalance Platform for SARS-CoV-2 Immuno-Diagnostics

Author:

Nilsson Per H.12,Al-Majdoub Mahmoud3,Ibrahim Ahmed3,Aseel Obaidullah4,Suriyanarayanan Subramanian1ORCID,Andersson Linnea1,Fostock Samir3,Aastrup Teodor3,Tjernberg Ivar56ORCID,Rydén Ingvar78,Nicholls Ian A.1ORCID

Affiliation:

1. Linnaeus University Centre for Biomaterials Chemistry, Department of Chemistry and Biomedical Sciences, Linnaeus University, SE-39182 Kalmar, Sweden

2. Department of Immunology, University of Oslo and Oslo University Hospital Rikshospitalet, Sognsvannsveien 20, NO-0372 Oslo, Norway

3. Attana AB, Greta Arwidssons Väg 21, SE-11419 Stockholm, Sweden

4. Medical Programme, Faculty of Medicine and Health Sciences, Linköping University, SE-58225 Linköping, Sweden

5. Department of Clinical Chemistry and Transfusion Medicine, Region Kalmar County, SE-39185 Kalmar, Sweden

6. Department of Biomedical and Clinical Sciences, Division of Inflammation and Infection, Linköping University, SE-58183 Linköping, Sweden

7. Department of Research, Region Kalmar County, SE-39185 Kalmar, Sweden

8. Department of Biomedical and Clinical Sciences, Division of Clinical Chemistry and Pharmacology, Linköping University, SE-58183 Linköping, Sweden

Abstract

Rapid and accurate serological analysis of SARS-CoV-2 antibodies is important for assessing immune protection from vaccination or infection of individuals and for projecting virus spread within a population. The quartz crystal microbalance (QCM) is a label-free flow-based sensor platform that offers an opportunity to detect the binding of a fluid-phase ligand to an immobilized target molecule in real time. A QCM-based assay was developed for the detection of SARS-CoV-2 antibody binding and evaluated for assay reproducibility. The assay was cross-compared to the Roche electrochemiluminescence assay (ECLIA) Elecsys® Anti-SARS-CoV-2 serology test kit and YHLO’s chemiluminescence immunoassay (CLIA). The day-to-day reproducibility of the assay had a correlation of r2 = 0.99, p < 0.001. The assay linearity was r2 = 0.96, p < 0.001, for dilution in both serum and buffer. In the cross-comparison analysis of 119 human serum samples, 59 were positive in the Roche, 52 in the YHLO, and 48 in the QCM immunoassay. Despite differences in the detection method and antigen used for antibody capture, there was good coherence between the assays, 80–100% for positive and 96–100% for negative test results. In summation, the QCM-based SARS-CoV-2 IgG immunoassay showed high reproducibility and linearity, along with good coherence with the ELISA-based assays. Still, factors including antibody titer and antigen-binding affinity may differentially affect the various assays’ responses.

Funder

Swedish Knowledge Foundation

Publisher

MDPI AG

Subject

Inorganic Chemistry,Organic Chemistry,Physical and Theoretical Chemistry,Computer Science Applications,Spectroscopy,Molecular Biology,General Medicine,Catalysis

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3