Hybrid Radiant Disinfection: Exploring UVC and UVB Sterilization Impact on the Mechanical Characteristics of PLA Materials

Author:

Aboamer Mohamed A.1ORCID,Alsuayri Ahmed S.2,Alassaf Ahmad1ORCID,Alqahtani Tariq M.1,Alresheedi Bakheet A.1,Saijari Ghazwan N.3,Osman Elamir A.4,Mohamed Nader A. Rahman5ORCID

Affiliation:

1. Department of Medical Equipment Technology, College of Applied Medical Sciences, Majmaah University, Majmaah 11952, Saudi Arabia

2. Erada and Mental Health Hospital, Al-Kharj 16246, Saudi Arabia

3. Department of Preventive Dental Science, College of Dentistry, Majmaah University, Majmaah 11952, Saudi Arabia

4. Biomedical Technology Department, Inaya Medical Colleges, Riyadh 13541, Saudi Arabia

5. Biomedical Engineering Department, Faculty of Engineering, Misr University for Science and Technology (MUST), Giza 12568, Egypt

Abstract

This study explores the impact of disinfection techniques on the mechanical properties of poly(lactic acid) (PLA), a crucial material in the production of medical implants, tissue engineering, orthopedic devices and drug delivery systems, owing to its biocompatibility and ease of manufacturing. The focus is on evaluating the effectiveness of ultraviolet (UV) type C (254 nm wavelength) and the combined use of type C and B (310 nm wavelength) disinfection methods. Fifteen tensile test specimens (ASTM D638) and fifteen compression test specimens (ASTM D695) were utilized to assess PLA’s mechanical properties, including yield strength, ultimate strength, and fracture strength. The investigation involved subjecting the specimens to the specified disinfection methods and evaluating these properties both before and after the disinfection process. In the tensile test, a statistically significant difference (p = 0) in yield displacement was observed among the three groups. Additionally, a notable difference (p = 0.047) in fracture displacement was identified between the untreated group and the UVC and UVB combination group. No discernible impact on yield or fracture forces was noted. In the compression test, there was a significant difference (p = 0.04) in yield displacement and a clear difference (p = 0.05) in fracture force between the untreated group and the UVC and UVB combination group. The hybrid combination of UVC and UVB disinfection techniques did not affect yield force in both tensile and compression tests. However, it demonstrated a clear impact on displacement, suggesting its potential as a promising disinfection technique in the medical field.

Funder

Majmaah University

Publisher

MDPI AG

Subject

Polymers and Plastics,General Chemistry

Reference35 articles.

1. Biodegradable poly(lactic acid) polymers;Kulkarni;J. Biomed. Mater. Res.,1971

2. Sterilization, toxicity, biocompatibility and clinical applications of polylactic acid/polyglycolic acid copolymers;Athanasiou;Biomaterials,1996

3. Biomedical Applications of Poly(Lactic Acid);Pawar;Recent Pat. Regen. Med.,2014

4. PGA (polyglycolic acid)-fiber-reinforced-PLA (polylactic acid) as an implant material for bone surgery;Christel;Int. Conf. Compos. Bio-Med. Eng.,1985

5. Zhou, C.R., and Li, L.H. (2004, January 17–21). Application of novel PLA/chitosan composite materials on bone tissue scaffolds. Proceedings of the Transactions—7th World Biomaterials Congress, Sydney, Australia.