The Early Effects on Tricuspid Annulus and Right Chambers Dimensions in Successful Tricuspid Valve Bicuspidization

Author:

Bieliauskienė Gintarė1ORCID,Kažukauskienė Ieva1,Janušauskas Vilius1ORCID,Zorinas Aleksejus1ORCID,Ručinskas Kęstutis1,Mainelis Antanas2ORCID,Zakarkaitė Diana1

Affiliation:

1. Clinic of Cardiovascular Diseases, Institute of Clinical Medicine, Faculty of Medicine, Vilnius University, M. K. Čiurlionio 21, 03101 Vilnius, Lithuania

2. Faculty of Mathematics and Informatics, Vilnius University, Naugarduko 24, 03225 Vilnius, Lithuania

Abstract

Background: It is unclear to what degree of tricuspid annulus (TA) reduction is necessary to achieve good postoperative results in surgical bicuspidization. The study aimed to evaluate TA and right heart chamber’s dimensions before and after heart surgery; and to compare TA parameters assessed by different modalities. Methods: Forty patients underwent mitral valve surgery with or without concomitant tricuspid valve (TV) bicuspidization. Preoperative and postoperative measurements of TA dimensions were performed prospectively using two-dimensional (2D) and three-dimensional (3D) transthoracic echocardiography (TTE). Additionally, preoperative transesophageal echocardiography (TOE) was performed in the operating room prior to surgery. Results: All patients had no or mild TR immediately after surgery. There was a significant reduction in 2D and 3D parameters of the TV and right chambers in the TV bicuspidization group. However, TV leaflets’ tethering parameters did not change significantly. Preoperative 3D TTE measurements were smaller than those obtained through 3D TOE in the operation room, before surgery under general anesthesia. The 2D systolic apical 4Ch diameter and the parasternal short axis diameter mainly represent the 3D minor axis of the TA and are smaller than its 3D major axis. Conclusions: Although bicuspidization results in a one-third reduction of the TV area, tethering of the TV leaflets remains unchanged. Moreover, 3D TOE parameters of the TV under general anesthesia are larger than preoperative 3D TTE measurements. Conventional 2D measurements are insufficient for evaluating the maximum diameter of the TA.

Publisher

MDPI AG

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3