Diagnostic Accuracy for Periprosthetic Joint Infection Does Not Improve by a Combined Use of Glucose and Leukocyte Esterase Strip Reading as Diagnostic Parameters

Author:

Haertlé MarcoORCID,Kolbeck Louisa,Macke ChristianORCID,Graulich Tilman,Stauß Ricarda,Omar Mohamed

Abstract

The diagnosis of periprosthetic infections (PJI) can be challenging in clinical practice because the clinical presentations of aseptic loosening and low-grade infections are similar. Semiquantitative evaluation of leukocyte esterase (LE) in synovial fluid using a urine strip test has already established itself as a diagnostic method over the past decade. The analysis of LE in synovial fluid leads to a high number of false-positive test results. In the present study, the value of a combined semiquantitative determination of glucose and LE in synovial fluid to improve the diagnosis of PJI was investigated. Over a 4-year period, 145 synovial samples were collected from patients who developed joint effusion after arthroplasty. LE and glucose test strips were considered as an index test for the diagnosis of PJI. A ++ or +++ LE and a negative glucose test strip reading were considered as positive test results. Modified diagnostic criteria for PJI as recommended by the Musculoskeletal Infection Society (MSIS) served as the reference test, except that intraoperative findings were excluded. Forty-six out of 145 samples were classified as septic complication according to the reference test. In regard to PJI, our data showed that combined use of LE and glucose strip test reading displayed a 98.0% specificity (95% confidence interval (CI): 95.2% to 100%), a 50% sensitivity (95% CI: 35.6% to 64.4%), a 92% positive predictive value (95% CI: 81.4% to 100.0%), and an 80.3% negative predictive value (95% CI: 73.2% to 87.4%). In contrast, the exclusive analysis of LE on the urine strip to diagnose PJI demonstrated a 90.9% specificity (95% CI: 85.2% to 96.6%), a 67.4% sensitivity (95% CI: 53.8% to 80.9%), a 77.5% positive predictive value (95% CI: 64.6% to 90.4%), and an 85.7% negative predictive value (5% CI: 79.0% to 92.4%). A combination of LE and glucose test pad reading is considered superior as a potential “rule-in” method for the diagnosis of PJI compared with LE test pad analysis alone. However, combined LE and glucose synovial fluid testing also demonstrated lower test sensitivity and thus diagnostic accuracy compared with LE analysis alone. Therefore, combined glucose and LE test pad analysis does not represent a sufficient diagnostic standard to exclude PJI with certainty.

Publisher

MDPI AG

Subject

General Medicine

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Diagnosing and Managing Infection in Total Ankle Replacement;Foot and Ankle Clinics;2024-03

2. ORAL FLUID AS AN OBJECT OF NONINVASIVE LABORATORY DIAGNOSTICS;Laboratornaya i klinicheskaya meditsina. Farmatsiya;2023

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3