Study on Effectiveness of Regional Risk Prioritisation in Reinforced Concrete Structures after Earthquakes

Author:

Işık Ercan1ORCID,Hadzima-Nyarko Marijana2ORCID,Radu Dorin3ORCID,Bulajić Borko4ORCID

Affiliation:

1. Department of Civil Engineering, Bitlis Eren University, Bitlis 13100, Türkiye

2. Department of Civil Engineering, Josip Juraj Strossmayer University of Osijek, Vladimira Preloga 3, 31000 Osijek, Croatia

3. Department of Civil Engineering, Transilvania University of Brașov, 500152 Braşov, Romania

4. Faculty of Techical Sciences, University of Novi Sad, Trg Dositeja Obradovića 6, 21000 Novi Sad, Serbia

Abstract

Depending on the characteristics of the existing buildings, earthquakes can cause damage at different levels and have a significant impact on the environment. The structural damages after the earthquakes have shown the importance of analysing both the existing and the damaged buildings. In this study, the Turkish rapid seismic assessment method, which was used for the existing building stock before a possible earthquake, was applied to the damaged reinforced concrete (RC) buildings after the 6 February earthquakes in Kahramanmaraş (Türkiye). The building data were used as a result of field observations in the provinces of Adıyaman, Hatay, and Kahramanmaraş, where the greatest destruction was caused by these earthquakes. Five RC buildings from each province were considered. The rapid assessment method was applied to a total of 15 buildings with different levels of damage. For this purpose, pre-earthquake images of the buildings were obtained, and an earthquake performance score was obtained for each building, taking into account the sustained damage during the earthquake. The primary aim of this study is to show the effects of structural irregularities on earthquake behaviour and to demonstrate the applicability of the rapid assessment methods used before the earthquake. The results obtained clearly demonstrate the effectiveness of rapid evaluation methods for existing building stock. Structural analyses were also carried out in this study to address the fact that the height of the ground storey is higher than the other storeys, which is one of the factors leading to a soft storey.

Publisher

MDPI AG

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3