MRI-Conditional Breast Tissue Expander: First In-Human Multi-Case Assessment of MRI-Related Complications and Image Quality

Author:

Schiaffino Simone1ORCID,Cozzi Andrea1ORCID,Pompei Barbara2,Scarano Angela Lia1,Catanese Carola1,Catic Armin2ORCID,Rossi Lorenzo34,Del Grande Filippo15ORCID,Harder Yves25ORCID

Affiliation:

1. Imaging Institute of Southern Switzerland (IIMSI), Ente Ospedaliero Cantonale (EOC), 6900 Lugano, Switzerland

2. Department of Plastic, Reconstructive and Aesthetic Surgery, Ente Ospedaliero Cantonale (EOC), 6900 Lugano, Switzerland

3. Oncology Institute of Southern Switzerland (IOSI), Ente Ospedaliero Cantonale (EOC), 6500 Bellinzona, Switzerland

4. Breast Unit of Southern Switzerland (CSSI), Ente Ospedaliero Cantonale (EOC), 6500 Bellinzona, Switzerland

5. Faculty of Biomedical Sciences, Università della Svizzera Italiana, 6900 Lugano, Switzerland

Abstract

This study aims to assess potential complications and effects on the magnetic resonance imaging (MRI) image quality of a new MRI-conditional breast tissue expander (Motiva Flora®) in its first in-human multi-case application. Twenty-four patients with 36 expanders underwent non-contrast breast MRI with T1-weighted, T2-weighted, and diffusion-weighted imaging (DWI) sequences on a 3 T unit before breast tissue expander exchange surgery, being monitored during and after MRI for potential complications. Three board-certified breast radiologists blindly and independently reviewed image quality using a four-level scale (“poor”, “sufficient”, “good”, and “excellent”), with inter-reader reliability being assessed with Kendall’s τb. The maximum diameters of RFID-related artifacts on T1-weighted and DWI sequences were compared with the Wilcoxon signed-rank test. All 24 examinations were completed without patient-related or device-related complications. The T1-weighted and T2-weighted sequences of all the examinations had “excellent” image quality and a median 11 mm (IQR 9–12 mm) RFID artifact maximum diameter, significantly lower (p < 0.001) than on the DWI images (median 32.5 mm, IQR 28.5–34.5 mm). DWI quality was rated at least “good” in 63% of the examinations, with strong inter-reader reliability (Kendall’s τb 0.837, 95% CI 0.687–0.952). This first in-human study confirms the MRI-conditional profile of this new expander, which does not affect the image quality of T1-weighted and T2-weighted sequences and moderately affects DWI quality.

Publisher

MDPI AG

Subject

General Medicine

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3