Smart Bioimpedance Device for the Assessment of Peripheral Muscles in Patients with COPD

Author:

Naranjo-Hernández David1ORCID,Reina-Tosina Javier1ORCID,Roa Laura M.1ORCID,Barbarov-Rostán Gerardo1ORCID,Ortega-Ruiz Francisco2ORCID,Cejudo Ramos Pilar2ORCID

Affiliation:

1. Biomedical Engineering Group, Department of Signal Theory and Communications, University of Seville, 41092 Seville, Spain

2. Medical Surgical Unit of Respiratory Diseases, Virgen del Rocío University Hospital, 41013 Seville, Spain

Abstract

Muscle dysfunction and muscle atrophy are common complications resulting from Chronic Obstructive Pulmonary Disease (COPD). The evaluation of the peripheral muscles can be carried out through the assessment of their structural components from ultrasound images or their functional components through isometric and isotonic strength tests. This evaluation, performed mainly on the quadriceps muscle, is not only of great interest for diagnosis, prognosis and monitoring of COPD, but also for the evaluation of the benefits of therapeutic interventions. In this work, bioimpedance spectroscopy technology is proposed as a low-cost and easy-to-use alternative for the evaluation of peripheral muscles, becoming a feasible alternative to ultrasound images and strength tests for their application in routine clinical practice. For this purpose, a laboratory prototype of a bioimpedance device has been adapted to perform segmental measurements in the quadriceps region. The validation results obtained in a pseudo-randomized study in patients with COPD in a controlled clinical environment which involved 33 volunteers confirm the correlation and correspondence of the bioimpedance parameters with respect to the structural and functional parameters of the quadriceps muscle, making it possible to propose a set of prediction equations. The main contribution of this manuscript is the discovery of a linear relationship between quadriceps muscle properties and the bioimpedance Cole model parameters, reaching a correlation of 0.69 and an average error of less than 0.2 cm regarding the thickness of the quadriceps estimations from ultrasound images, and a correlation of 0.77 and an average error of 3.9 kg regarding the isometric strength of the quadriceps muscle.

Funder

Junta de Andalucía

Mutua Madrileña Foundation

Publisher

MDPI AG

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3