Affiliation:
1. Rehabilitation Medicine Department, National Institutes of Health Clinical Center, Bethesda, MD 20892, USA
Abstract
Accurately estimating knee joint angle during walking from surface electromyography (sEMG) signals can enable more natural control of wearable robotics like exoskeletons. However, challenges exist due to variability across individuals and sessions. This study evaluates an attention-based deep recurrent neural network combining gated recurrent units (GRUs) and an attention mechanism (AM) for knee angle estimation. Three experiments were conducted. First, the GRU-AM model was tested on four healthy adolescents, demonstrating improved estimation compared to GRU alone. A sensitivity analysis revealed that the key contributing muscles were the knee flexor and extensors, highlighting the ability of the AM to focus on the most salient inputs. Second, transfer learning was shown by pretraining the model on an open source dataset before additional training and testing on the four adolescents. Third, the model was progressively adapted over three sessions for one child with cerebral palsy (CP). The GRU-AM model demonstrated robust knee angle estimation across participants with healthy participants (mean RMSE 7 degrees) and participants with CP (RMSE 37 degrees). Further, estimation accuracy improved by 14 degrees on average across successive sessions of walking in the child with CP. These results demonstrate the feasibility of using attention-based deep networks for joint angle estimation in adolescents and clinical populations and support their further development for deployment in wearable robotics.
Funder
National Institutes of Health Clinical Center