Effects of Cardiac Contractility Modulation Electrodes on Tricuspid Regurgitation in Patients with Heart Failure with Reduced Ejection Fraction: A Pilot Study

Author:

Masarone DanieleORCID,Kittleson Michelle M.,De Vivo Stefano,D’Onofrio Antonio,Rao IshuORCID,Ammendola Ernesto,Errigo Vittoria,Martucci Maria L.,Nigro GerardoORCID,Pacileo Giuseppe

Abstract

Background: Cardiac contractility modulation (CCM) is an innovative therapy for heart failure with reduced ejection fraction delivered by a cardiac implantable device (Optimizer Smart®). One of the most prominent periprocedural complications common to all cardiac implantable devices (CIDs) is tricuspid regurgitation (TR) due to the placement of the right ventricular endocardial leads. To date, no published studies have assessed the changes in the TR degree in patients with heart failure with reduced ejection fraction (HFrEF) who received an implantable cardioverter-defibrillator (ICD) after the implantation of cardiac contractility modulation therapy devices. Objective: This study aimed to evaluate the effect of the implantation of the trans-tricuspid leads required to deliver CCM therapy on the severity of TR in patients with HFrEF who previously underwent ICD implantation. Methods: We enrolled 30 HFrEF patients who underwent CCM therapy between November 2020 and October 2021. For all the patients, echocardiographic evaluations of TR were performed according to current guidelines 24 h before and six months after the Optimizer Smart® implant was applied. Results: At the 6-month follow-up, the grade of TR remained unchanged compared to the preimplant grade. The value of the vena contracta (VC) of TR was 0.40 ± 0.19 cm in the preimplant period and 0.45 ± 0.21 cm at the 6-month follow-up (p = 0.33). Similarly, the TR proximal isovelocity surface area (PISA) radius value was unchanged at follow-up (0.54 ± 0.22 cm vs. 0.62 ± 0.20 cm; p = 0.18). No statistically significant difference existed between the preimplant VC and PISA radius values, irrespective of the device type. Conclusions: The implantation of right ventricular electrodes for the delivery of CCM therapy did not worsen tricuspid regurgitation in patients with HFrEF and ICD.

Publisher

MDPI AG

Subject

General Medicine

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3