Physico-Mechanical Properties and Bonding Performance of Graphene-Added Orthodontic Adhesives

Author:

Liu Shiyao1,El-Angbawi Ahmed1,Rosa Vinicius234ORCID,Silikas Nick1ORCID

Affiliation:

1. Division of Dentistry, University of Manchester, Manchester M13 9PL, UK

2. Centre for Advanced 2D Materials and Graphene Research Centre, National University of Singapore, Singapore 119085, Singapore

3. Faculty of Dentistry, National University of Singapore, 11 Lower Kent Ridge Road, Singapore 119085, Singapore

4. Oral Care Health Innovations and Design Singapore (ORCHIDS), National University of Singapore, 11 Lower Kent Ridge Road, Singapore 119085, Singapore

Abstract

This study aimed to assess the key physico-mechanical properties and bonding performance of orthodontic adhesives with graphene addition for bonding a fixed retainer. Transbond LR (3M) and Transbond LV (3M) with no graphene were set as the control groups. Graphene was added into LR and LV at concentrations of 0.01 wt%, 0.05 wt% and 0.1 wt%. The stickiness of the uncured samples (n = 5) and real-time degree of conversion (DC) of the samples (n = 3) were measured over a 24-h period using Fourier-transform infrared spectroscopy. The hardness and other mechanical parameters, including the Martens hardness (HM), indentation modulus (EIT), elastic index (ηIT) and creep (CIT), were measured (n = 5). To measure the shear bond strength (SBS), adhesive composites were applied using a mold to bond the retainer wire to the lingual surfaces of bovine incisors (n = 10). Fracture modes subsequent to the SBS test were examined under light microscopy. Statistical analysis was conducted using ANOVA and Tukey tests (α = 0.05). In the LR groups, the LR + 0.01 showed the highest SBS (12.6 ± 2.0 MPa) and HM (539.4 ± 17.9 N/mm2), while the LV + 0.05 (7.7 ± 1.1 MPa) had the highest SBS and the LV + 0.1 had the highest HM (312.4 ± 17.8 N/mm2) among the LV groups. The most frequent failure mode observed was adhesive fracture followed by mixed fracture. No statistical difference was found between the graphene-added groups and the control groups in terms of the EIT, ηIT and CIT, except that the CIT was significantly lower in the LR + 0.01 than in the control group. Graphene addition had no significant adverse effect on the stickiness and DC of both LR and LV.

Publisher

MDPI AG

Reference73 articles.

1. Long-term experience with direct-bonded retainers: Update and clinical advice;Zachrisson;J. Clin. Orthod.,2007

2. Fixed Orthodontic Retainers: A Review;Kartal;Turk. J. Orthod.,2019

3. Fixed retention: Pitfalls and complications;Kucera;Br. Dent. J.,2021

4. Long-term follow-up of maxillary fixed retention: Survival rate and periodontal health;Dietrich;Eur. J. Orthod.,2015

5. What causes failure of fixed orthodontic retention?—Systematic review and meta-analysis of clinical studies;Grocholewicz;Head Face Med.,2021

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3