Evaluation of Long-Term Flow Controller for Monitoring Gases and Vapors in Buildings Impacted by Vapor Intrusion

Author:

Rossner Alan1,Wick David P.2ORCID,Lutes Christopher3ORCID,Stone Benjamin1,Crimi Michelle1

Affiliation:

1. Institute for Sustainable Environment, Clarkson University, Potsdam, NY 13699, USA

2. School of Individualized Study, Rochester Institute of Technology, Rochester, NY 14623, USA

3. Jacobs Engineering Group Inc., Dallas, TX 75201, USA

Abstract

This study evaluated the use of a long-term capillary flow controller paired with an evacuated canister for indoor air exposure monitoring in a vapor intrusion (VI) environment with trichloroethylene in comparison to the traditional method utilizing a diaphragm flow controller. Traditionally, air sampling with 6 L evacuated canisters equipped with diaphragm flow controllers has been best suited for 8 to 24 h samples. New advances in capillary flow controllers can extend sampling to up to 3 weeks by reducing flow rates to 0.1 milliliters min−1. During six 2 wk sampling events, conventional diaphragm flow controller canisters were used to collect 24 h samples simultaneously with capillary flow controllers collecting 2 wk samples. Testing was performed at four indoor locations in buildings impacted by VI with co-located samples for each method at each location. All samples were analyzed using GC/MS, and the results were statistically analyzed to produce a direct comparison of the two sampling systems. Ninety-two percent of the 14 d capillary samples were within the 95% levels of agreement of the average concentration of the diaphragm flow controllers. The ability to collect 14 days of data, with less occupant disturbance, allows for improved exposure assessments and thus improved risk management decisions.

Funder

Environmental Security Technology Certification Program

Publisher

MDPI AG

Subject

Health, Toxicology and Mutagenesis,Public Health, Environmental and Occupational Health

Reference43 articles.

1. Risk-Based Evaluation of Total Petroleum Hydrocarbons in Vapor Intrusion Studies;Brewer;Int. J. Environ. Res. Public Health,2013

2. Relationship between vapor intrusion and human exposure to trichloroethylene;Archer;J. Environ. Sci. Health Part A,2015

3. Holton, C., Luo, E., Guo, Y., Dahlen, P., and Johnson, P.C. (2013, January 18–21). Multi-Year Monitoring of a House Over a Dilute CHC Plume: Implications for Pathway Assessment Using Indoor Air Sampling and Forced Under-Pressurization Tests. Proceedings of the 23rd Annual International Conference on Soil, Water, Energy & Air, Association for Environmental Health Sciences (AEHS 2013), San Diego, CA, USA.

4. Adverse birth outcomes and maternal exposure to trichloroethylene and tetrachloroethylene through soil vapor intrusion in New York State;Forand;Environ. Health Perspect.,2012

5. Exposure to volatile organic compounds and associated health risks in Windsor, Canada;Khanchi;Atmos. Environ.,2015

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3