Evaluation of Different Natural Ventilation Strategies by Monitoring the Indoor Air Quality Using CO2 Sensors

Author:

Sánchez-Fernández Ana1,Coll-Aliaga Eloína1,Lerma-Arce Victoria1ORCID,Lorenzo-Sáez Edgar1ORCID

Affiliation:

1. ITACA Research Institute, Universitat Politècnica de València, Camí de Vera s/n, 46022 Valencia, Spain

Abstract

Indoor air quality is a characteristic that depends on air pollutants inside a building and that can be affected by different ventilation strategies. There is strong evidence linking poor indoor air quality (IAQ) and harmful health effects, especially on vulnerable collectives, such as children in schools. Due to this concern, this work aims to provide guidance on the design of highly efficient ventilation strategies to improve the air quality of schools’ classrooms. For this, IAQ monitoring has been carried out in eight educational in real conditions centres using CO2 concentration as an IAQ indicator. Variables such as the presence of students and their number, activity developed in the classroom and ventilation strategy used together with break time duration have been also recorded to analyse their influence on CO2 concentration levels. Concluding results have allowed us to determine the maximum number of students allowed in a closed room to maintain CO2 levels at normal concentrations and the time needed to reduce these CO2 levels depending on the ventilation strategy adopted. Moreover, it has been discussed how surrounding school conditions (pollution or noise) and the building isolation are impacting the final IAQ in the classrooms studied.

Publisher

MDPI AG

Subject

Health, Toxicology and Mutagenesis,Public Health, Environmental and Occupational Health

Reference24 articles.

1. Influence of Indoor Environmental Quality on Human Health and Productivity—A Review;Mujan;J. Clean. Prod.,2019

2. Indoor Air Quality Investigation According to Age of the School Buildings in Korea;Yang;J. Environ. Manag.,2009

3. Persily, A.K. (1997). Evaluating Building IAQ and Ventilation with Indoor Carbon Dioxide, American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.

4. (1998). Ventilation for Buildings-Design Criteria for the Indoor Environment. Standard No. CR 1752:1998.

5. Indoor Environmental Quality Classification of School Environments by Monitoring PM and CO2 Concentration Levels;Schibuola;Atmos. Pollut. Res.,2020

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献