Clinical Considerations for Implanted Neurological Devices in Patients Undergoing Hyperbaric Oxygen Therapy: A Case Report and Review of Manufacturer Guidelines

Author:

Schiavo Simone123ORCID,Brenna Connor T. A.1ORCID,Bhatia Anuj13ORCID,Middleton William J.123,Katznelson Rita123

Affiliation:

1. Department of Anesthesiology & Pain Medicine, University of Toronto, Toronto, ON M5G 1E2, Canada

2. Hyperbaric Medicine Unit, Toronto General Hospital, Toronto, ON M5G 2C4, Canada

3. Department of Anesthesia and Pain Management, University Health Network, Toronto, ON M5G 2C4, Canada

Abstract

Patients with implanted medical devices are increasingly referred for hyperbaric oxygen therapy (HBOT), and the safety of exposing some of these devices to hyperbaric environments has not previously been explored. There is a paucity of evidence surrounding the management of implanted neurological devices such as neurostimulators and intrathecal drug delivery (IDD) pumps in the context of HBOT. However, these devices can be expected to harbor unique risks; for example, vacant space in the reservoir of an implanted IDD pump may change in pressure and volume during the compression and decompression phases of HBOT, resulting in a damaged or dysfunctional device. We present the case of a 27-year-old woman with cerebral palsy referred for HBOT to manage a necrotizing soft tissue infection cultured from a dehiscent abdominal wound at the previous implantation site of an intrathecal baclofen pump. An HBOT protocol was ultimately chosen in partnership with the patient and her family, but treatment was not performed due to a paucity of evidence that the implanted IDD pump could safely withstand hyperbaric exposure. In this review, we have synthesized manufacturer recommendations regarding the management of implanted neurological devices before, during, and after HBOT to inform future decision-making in this setting. Among these recommendations, we highlight that neurostimulators should be switched off for the duration of HBOT and implanted pumps should be refilled prior to each treatment session to minimize empty reservoir space.

Publisher

MDPI AG

Subject

Health, Toxicology and Mutagenesis,Public Health, Environmental and Occupational Health

Reference41 articles.

1. Prevalence of Implanted Medical Devices in Medicine Inpatients;Kuder;J. Patient Saf.,2018

2. Hunter, C.W., Lee, E.T., Masone, R., and Deer, T.R. (2016). Atlas of Implantable Therapies for Pain Management, Springer.

3. Spinal Cord Stimulation: Clinical Efficacy and Potential Mechanisms;Sdrulla;Pain Pract.,2018

4. Deep brain stimulation: Current challenges and future directions;Lozano;Nat. Rev. Neurol.,2019

5. Deer, T.R., and Pope, J.E. (2016). Atlas of Implantable Therapies for Pain Management, Springer.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3