Abstract
This study aimed to examine the potential sex differences in wide-pulse high-frequency neuromuscular electrical stimulation (WPHF NMES)-evoked force. Twenty-two subjects (10 women) completed this study. Prior to the stimulation, the visual analogue scale (VAS) for discomfort and the rating of perceived exertion (RPE) were measured, followed by the isometric strength of the dominant elbow flexor muscles. The subjects then completed ten, 10-s on 10-s off WPHF NMES (pulse width: 1 ms, frequency: 100 Hz) at maximum tolerable intensities. The subjects’ RPE was recorded after each set, and the VAS was measured following the last stimulation. The stimulation induced significant increase in discomfort for both sexes, with women having greater discomfort than men (men: 22.4 ± 14.9 mm, women: 39.7 ± 12.7 mm). The stimulation amplitude was significantly greater in men than in women (men: 16.2 ± 6.3 mA, women: 12.0 ± 4.5 mA). For the evoked force, only the relative NMES-evoked force was found greater in women than in men (men: 8.96 ± 6.51%, women: 17.08 ± 12.61%). In conclusion, even at the maximum tolerable intensity, WPHF NMES evoked larger relative elbow flexion force in women than in men, with women experiencing greater discomfort.
Funder
National Aeronautics and Space Administration
Subject
Physical Therapy, Sports Therapy and Rehabilitation,Orthopedics and Sports Medicine
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献