Abstract
The airtightness of a building has a significant impact on energy savings, structural longevity, and indoor air quality for occupants. Therefore, it is essential to accurately measure the airtightness of buildings, though the widely used fan pressurization method suffers from several shortcomings. For this reason, transient methods have recently emerged to assess airtightness by monitoring pressure changes over time, but studies using transient methods in this field are rare. In this study, we selected three representative buildings to conduct field tests to verify the practical applicability of the improved transient method. To verify the results of the transient method, we conducted a comparison experiment with the blower door test: a widely used measurement method. When measuring the effective leakage area, the average standard deviation of the transient method was 0.903 cm2, which was much smaller than the blower door test result of 1.488 cm2. In addition, the recorded standard errors ranged from 0.197 cm2 to 0.816 cm2 for the transient method and from 0.269 cm2 to 1.801 cm2 for the blower door test. Notably, the transitional method was more reproducible than the blower door test while showing similar accuracy. Given these results, it is expected that the improved transitional method can be used to evaluate airtightness performance in the field.
Funder
Korea Agency for Infrastructure Technology Advancement
Subject
Energy (miscellaneous),Energy Engineering and Power Technology,Renewable Energy, Sustainability and the Environment,Electrical and Electronic Engineering,Control and Optimization,Engineering (miscellaneous),Building and Construction
Reference21 articles.
1. Proposed Existing Building Diagnosis Framework for Energy Efficiency Improvement;Han;Case Stud. Therm. Eng.,2023
2. Jun, Y.J., Ahn, S.H., and Park, K.S. (2021). Improvement Effect of Green Remodeling and Building Value Assessment Criteria for Aging Public Buildings. Energies, 14.
3. A Perspective on Fifty Years of Natural Ventilation Research;Etheridge;Build. Environ.,2015
4. Airtightness Measurement of an Outdoor Chamber Using the Pulse and Blower Door Methods under Various Wind and Leakage Scenarios;Zheng;Build. Environ.,2020
5. (2023, September 01). Air Sealing Your Home|Department of Energy, Available online: https://www.energy.gov/energysaver/air-sealing-your-home.