Photovoltaic Thermal Heat Pump Assessment for Power and Domestic Hot Water Generation

Author:

Zhou Chao12ORCID,Riaz Ahmad34ORCID,Wang Jingjing1,Zhang Jili3,Xu Lin5

Affiliation:

1. School of Architectural Engineering, Weifang University of Science and Technology, Weifang 262700, China

2. Shandong Provincial University Laboratory for Protected Horticulture, Weifang 262700, China

3. Faculty of Infrastructure Engineering, Dalian University of Technology, Dalian 116024, China

4. Department of Architectural Engineering, University of Engineering & Technology, Lahore 54890, Pakistan

5. Shandong Fuyuan Architectural Design Co., Ltd., Weifang 261000, China

Abstract

The efficient utilization of solar energy significantly contributes to energy efficiency in buildings. Solar photovoltaic thermal (PVT) heat pumps, a hybrid of photovoltaic and solar-assisted heat pumps, have demonstrated a significant development trend due to their multi-generational capacity for heating, power, and cooling with reliable operational performance. This research work presents and investigates a single-stage compression PVT heat pump system, along with the operation principle of the system’s heating and power co-generation throughout the winter and transitional season. The construction of the testing facility, data reduction, error analysis, and performance evaluation indices of the system are all explained theoretically. A continuous experiment research project focusing on system heating and power performance was carried out in Dalian during the transition season (November in this study) and winter season (December in this study) as part of our investigation into the potential uses for space heating, residential hot water, and power supply in northern China. The findings of the experimental research demonstrate that the proposed system can generate electricity and heat at high efficiency during the winter and transitional seasons, with long-term stable performance. The system’s average heating COPt is 5 during the transitional season and 4.4 during the winter season. Meanwhile, the average photovoltaic power efficiency under both weather conditions is 11.9% and 10.2%, with a peak value of 15.7% and 12.0%, respectively. Additionally, the system compression ratio’s variation range is 2 to 3.88, which is lower than the standard heat pump system. As a result, the entire system heating operating process remains constant.

Funder

Shandong Provincial Natural Science Foundation

Weifang Science and Technology Development Project

Research Start-up Funding Project for High-level Talents of Weifang University of Science and Technology

Special Subject Project of Discipline Construction of Weifang University of Science and Technology

Publisher

MDPI AG

Subject

Energy (miscellaneous),Energy Engineering and Power Technology,Renewable Energy, Sustainability and the Environment,Electrical and Electronic Engineering,Control and Optimization,Engineering (miscellaneous),Building and Construction

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献