Exergy-based methods provide engineers with the best information with respect to options for improving the overall thermodynamic efficiency of an energy conversion system. This paper presents the results of an advanced exergy analysis of an air-to-water reversible heat pump whose performance was analyzed with respect to different working fluids. Environmentally deleterious refrigerants, i.e., R410A and R134a (baselines), and their eco-friendly replacements (R290, R152a, R1234ze(E), and R1234yf) were selected. The evaluations were conducted under the same operating conditions (i.e., with the same cooling and heating demands and outdoor temperatures). Based on conventional exergy analysis, it was determined that different priorities should be given for the thermodynamic improvement of the components according to which heating and cooling modes of the system are in use. Therefore, integrated parameters, i.e., the annual values of exergy destruction, were applied for further analysis. The results obtained showed that the heat pump using R410A provided the largest degree of annual exergy destruction estimated on the basis of conventional exergy analysis (5913 kWh), whereas the heat pump using R290 offered the lowest one (4522 kWh). The annual exergy destruction of the R410A cycle with only unavoidable irreversibilities could be decreased by 50%. In this case, compared to R410A and R134a, R152a and R290 provided lower values of the total annual unavoidable aspects of exergy destruction. Considering technological limitations, when removing all the avoidable irreversibilities within the air exchanger, the largest decrease in the total exergy destruction within the system could be reached. The results obtained from the analysis of the removable irreversibilities showed that the mutual interactions between the compressor, evaporator, and condenser were weak. Finally, it was concluded that, from a thermodynamic point of view, the adoption of R152a and R290 in reversible air-to-water heat pumps as replacements for R410A and R134a is advisable.

Publisher

MDPI AG

Subject

Energy (miscellaneous),Energy Engineering and Power Technology,Renewable Energy, Sustainability and the Environment,Electrical and Electronic Engineering,Control and Optimization,Engineering (miscellaneous),Building and Construction

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3