Abstract
An energy-efficient thermal control management method for space remote sensors using optical, mechanical, electrical, and thermal integration is proposed. The satellite power resources are insufficient, so an energy-efficient loop heat pipe (LHP) is designed for six intermittently operating detectors. The charge-coupled device (CCD) has a total heat generation of 72 W and operates for 8 min per orbital cycle. The LHP includes a capillary pump, six cold plates, and two radiators. The working fluid of the LHP is high-purity ammonia and the material of the wick is ceramic. The drive power on the capillary pump evaporator automatically switches between 30 W and 90 W depending on the operating mode of the remote sensor, resulting in an average power saving of about 58.2% compared to a conventional LHP. For the optical structure, a three-stage insulation technology was developed to save heater power and improve temperature stability. A transient numerical simulation model of the LHP was developed to study the vapor–liquid zone of two radiators under the condition of rapid power change. Vacuum thermal tests were conducted and the test data agreed well with the numerical simulation results. The in-orbit temperature data showed that the temperature fluctuations of the optical structure and CCD were less than ±0.2 °C and ±0.8 °C, respectively.
Funder
National Key R&D Program of China
Subject
Energy (miscellaneous),Energy Engineering and Power Technology,Renewable Energy, Sustainability and the Environment,Electrical and Electronic Engineering,Control and Optimization,Engineering (miscellaneous),Building and Construction
Reference16 articles.
1. The study of high resolution stereo mapping satellite;Cao;Natl. Remote Sens. Bull.,2021
2. Simulation and experimental study of mechanically pumped two-phase loop for CCD;Zhao;J. Beijing Univ. Aeronaut. Astronaut.,2019
3. Defisel, J.M. (1997, January 14–17). Lessons learned from the thermal design of an instrument (EIT, the Extreme-UV Imaging Telescope) onboard SOHO. Proceedings of the 27th International Conference on Environmental Systems, University of Liège, Lake Tahoe, NV, USA.
4. Sic focal plane assembly for the Pleiades HR Satellite;Pranyies;Proc. SPIE-Int. Soc. Opt. Eng.,2004
5. Thermal design of detector for the solar X-Ray and extreme ultraviolet imager;Li;J. Thermophys. Heat Transf.,2019