Comparison of Macintosh Laryngoscope, King Vision®, VividTrac®, AirAngel Blade®, and a Custom-Made 3D-Printed Video Laryngoscope for Difficult and Normal Airways in Mannequins by Novices—A Non-Inferiority Trial

Author:

Bacher Viktor12,Németh Márton1,Rendeki Szilárd12,Tornai Balázs1,Rozanovic Martin1ORCID,Pankaczi Andrea1,Oláh János1,Farkas József23,Chikhi Melánia1,Schlégl Ádám24ORCID,Maróti Péter25ORCID,Nagy Bálint12

Affiliation:

1. Department of Anesthesiology and Intensive Medicine, Medical School, University of Pecs, H-7624 Pecs, Hungary

2. Medical Skills Education and Innovation Centre, Medical School, University of Pécs, H-7624 Pecs, Hungary

3. Department of Anatomy, Medical School, University of Pécs, H-7624 Pecs, Hungary

4. Department of Orthopedics, Medical School, University of Pécs, H-7624 Pecs, Hungary

5. 3D Printing & Visualization Centre, Medical School, University of Pécs, H-7624 Pecs, Hungary

Abstract

Background: Endotracheal intubation (ETI) is a cornerstone of airway management. The gold standard device for ETI is still the direct laryngoscope (DL). However, video laryngoscopes (VLs) are now also widely available and have several proven advantages. The VL technique has been included in the major airway management guidelines. During the COVID-19 pandemic, supply chain disruption has raised demand for 3D-printed medical equipment, including 3D-printed VLs. However, studies on performance are only sparsely available; thus, we aimed to compare 3D-printed VLs to the DL and other VLs made with conventional manufacturing technology. Methods: Forty-eight medical students were recruited to serve as novice users. Following brief, standardized training, students executed ETI with the DL, the King Vision® (KV), the VividTrac® (VT), the AirAngel Blade® (AAB), and a custom-made 3D-printed VL (3DVL) on the Laerdal® airway management trainer in normal and difficult airway scenarios. We evaluated the time to and proportion of successful intubation, the best view of the glottis, esophageal intubation, dental trauma, and user satisfaction. Results: The KV and VT are proved to be superior (p < 0.05) to the DL in both scenarios. The 3DVL’s performance was similar (p > 0.05) or significantly better than that of the DL and mainly non-inferior (p > 0.05) compared to the KV and VT in both scenarios. Regardless of the scenario, the AAB proved to be inferior (p < 0.05) even to the DL in the majority of the variables. The differences between the devices were more pronounced in the difficult airway scenario. The user satisfaction scores were in concordance with the aforementioned performance of the scopes. Conclusions: Based upon our results, we cannot recommend the AAB over the DL, KV, or VT. However, as the 3DVL showed, 3D printing indeed can provide useful or even superior VLs, but prior to clinical use, meticulous evaluation might be recommended.

Funder

University of Pécs

Publisher

MDPI AG

Reference54 articles.

1. Dental injuries resulting from tracheal intubation—A retrospective study;Vogel;Dent. Traumatol.,2009

2. Complications and failure of airway management;Cook;Br. J. Anaesth.,2012

3. Pacheco-Lopez, P.C., Berkow, L.C., Hillel, A.T., and Akst, L.M. (2014). Respiratory Care, American Association for Respiratory Care.

4. Intubation Practices and Adverse Peri-intubation Events in Critically Ill Patients From 29 Countries;Russotto;JAMA,2021

5. Difficult Airway Society 2015 guidelines for management of unanticipated difficult intubation in adults;Frerk;Br. J. Anaesth.,2015

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3