Abstract
The high pressure turbine nozzle guide vane of a modern aeroengine experiences large heat loads and thus requires both highly effective internal and external cooling. This can be accomplished with double-wall effusion cooling, which combines impingement, pin-fin and effusion cooling. The combination of three cooling mechanisms causes high pressure losses, increasing potential for the migration of coolant towards low pressure regions, subsequently starving effusion holes on the leading edge of coolant supply. This paper presents a low order flow network model to rapidly assess the pressure and mass flow distributions through such cooling schemes for a flexible set of geometric and flow conditions. The model is subsequently validated by a series of experiments with varying mainstream pressure gradients. Results from the model are used to indicate design parameters to reduce the effect of coolant migration, and to minimise the risk of destructive hot gas ingestion.
Funder
Engineering and Physical Sciences Research Council
Rolls-Royce
Subject
Mechanical Engineering,Energy Engineering and Power Technology,Aerospace Engineering
Cited by
9 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献