Thermodynamic Performance of a Cogeneration Plant Driven by Waste Heat from Cement Kilns Exhaust Gases

Author:

Mungyeko Bisulandu Baby-Jean Robert12ORCID,Ilinca Adrian3ORCID,Tsimba Mboko Marcel4,Mbozi Mbozi Lucien4

Affiliation:

1. Laboratoire de Recherche en Energie Eolienne (LREE), Université du Québec à Rimouski (UQAR), 300 Allée des Ursulines, Rimouski, QC G5L 3A1, Canada

2. Institut de Recherche Futuris—Futuris Research Institute (InReF), OEFC & Faculté Polytechnique, Université Kongo, Mbanza-Ngungu B.P. 202, Democratic Republic of the Congo

3. Department of Mechanical Engineering, École de Technologie Supérieure, Montreal, QC H3C 1K3, Canada

4. Faculté Polytechnique, Université Président Joseph Kasa-Vubu, Boma B.P. 314, Democratic Republic of the Congo

Abstract

The dwindling and scarcity of fossil energy sources is the basis of the energy transition, where renewable resources are increasingly valued. The purpose of the cogeneration system studied in this article is to recover the residual heat from the gases coming out of the chimneys of the cement kilns, to produce at the same time the electricity and the heat required for offices and residential houses of cement workers. Cement kilns are reputed to be energy-intensive, generating excessive heat losses. These heat losses are found mainly in the conduction–convective and radiative modes, representing about 26% of the overall heat input to the system. Nevertheless, the gases at the chimney outlet can still have temperatures between 250 and 350 °C, which presents a non-negligible potential for a cogeneration system. This study compares the thermal performance of different cogeneration plant configurations (KCA, KCB, and KCC systems) using the Kalina cycle to determine the best one. Several assumptions were made to reduce the complexity of the model. MATLAB and Excel software were used to solve the system of equations. After extensive analysis of the results, the KCA system showed the best performance, compared to the KCB and KCC systems, with a thermal efficiency of 22.15%, an exergy efficiency of 45.12%, and a net electrical capacity of 2565.03 kWe. Model sensitivity to concentration, temperature, and pressure variations also gave the KCA system the best-performing system. Evaluation of the excess heat flux removed from the process yields values of 7368.20 kW, 7421.86 kW, and 8094.15 kW for the KCA, KCB, and KCC systems. The results of this article serve as a decision support tool for installing the cogeneration system via the Kalina cycle in cement installations.

Publisher

MDPI AG

Subject

Energy (miscellaneous),Energy Engineering and Power Technology,Renewable Energy, Sustainability and the Environment,Electrical and Electronic Engineering,Control and Optimization,Engineering (miscellaneous),Building and Construction

Reference48 articles.

1. Modeling of the Thermochemical Conversion of Biomass in Cement Rotary Kiln;Bisulandu;Waste Biomass Valorization,2021

2. Simulation of Rotary Cement Kilns Using a One-Dimensional Model;Mujumdar;Chem. Eng. Res. Des.,2006

3. Bisulandu, B.J.R.M., and Pongo, P. (2014). Septième Édition du COlloque FRancophone en Energie, Environnement, Economie et Thermodynamique-COFRET’14, COFRET. [7th ed.].

4. Dynamic simulation of a trigeneration system using an absorption cooling system and building integrated photovoltaic thermal solar collectors;Jalalizadeh;J. Build. Eng.,2021

5. Design of Total Site-Integrated TrigenerationSystem using trigeneration cascade analysis considering transmission losses and sensitivity analysis;Jamaluddin;Energy,2022

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3