Abstract
Removal of hexavalent chromium had attracted much attention as it is a hazardous contaminant. An electrocoagulation-like technology electro-reduction was applied. The chromium (VI) in the wastewater was reduced to chromium (III) by the electron supplied by electricity power and Fe2+, formed from corrosion of steel electrodes in acidic conditions. The mechanism and parameters affecting the reaction were investigated. The results optimized by response surface methodology indicated that the influence of single factor on the reduction efficiency followed the order: A: dosage of H2SO4 > C: reaction time > D: reaction temperature > B: current intensity. The reduction efficiency was hardly affected by current intensity, while it was increased with the increasing of reaction time and acid concentration. The reducing agent, Fe2+ an and extra free electron, acted as a reducing agent and could easily reduce hexavalent chromium to trivalent chromium at high temperatures in an acidic medium.
Funder
National Natural Science Foundation of China
Subject
Process Chemistry and Technology,Chemical Engineering (miscellaneous),Bioengineering
Cited by
55 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献