An Innovative Clinical Evaluation Protocol after Total Ankle Arthroplasty: A Pilot Study Using Inertial Sensors and Baropodometric Platforms

Author:

Mazzotti Antonio12ORCID,Arceri Alberto1ORCID,Abdi Pejman1,Artioli Elena1ORCID,Zielli Simone Ottavio1,Langone Laura1ORCID,Ramponi Laura1,Ridolfi Arianna2,Faldini Cesare12,Brognara Lorenzo2

Affiliation:

1. 1st Orthopaedics and Traumatologic Clinic, IRCCS Istituto Ortopedico Rizzoli, 40136 Bologna, Italy

2. Department of Biomedical and Neuromotor Sciences (DIBINEM), Alma Mater Studiorum University of Bologna, 40123 Bologna, Italy

Abstract

Background: Total ankle arthroplasty (TAA) has grown in popularity and indications, with encouraging results over time. Today, preoperative and postoperative evaluations are mainly performed using clinical test and diagnostic imaging, but there is a deficiency in objectively evaluating the biomechanics of the foot and ankle, which serve as the functional markers for monitoring the effectiveness and outcomes of surgery. Inertial measurement units associated with plantar pressure measurements may provide an accurate and reliable method of evaluating function through the analysis of gait and ankle joint mobility. The aim of this study was to introduce an innovative technology, to assess its accuracy and feasibility compared to standard clinical assessment methods and to objectify kinematic outcomes in patients with end-stage ankle OA before and after TAA surgery. Methods: A consecutive series of eight patients with symptomatic end-stage osteoarthritis and treated with TAA was prospectively evaluated using clinical scores (AOFAS, MOxFQ, VAS, SF-36, 17-IFFI), physical tests (FPI, ALT), plantar pressure measurements with FLEX EPS/R2 Letsense® baropodometric platform, gait analysis and wearable sensors-based ankle motion and kinematic outcomes using Wiva Science inertial sensors by Letsense®. Data were collected preoperatively and 4 months after surgery. Results: All PROMs exhibited statistical significance in improvement from pre- to postoperative periods, except for one. Physical examinations showed no significant changes of the foot shape and alignment. Plantar pressure analyses revealed no significant changes in static and dynamic evaluations, but a more uniform distribution of plantar pressure was observed between the two periods. Inertial sensor parameters demonstrated no significant differences, except for a significant reduction in stride length and step length for the operated foot after surgery. Conclusions: Gait analysis using inertial sensors and plantar pressure measurements offer ease of handling, cost effectiveness, portability and swift data reading, making them highly appealing for widespread clinical use. Integrating these tools into the routine assessments of patients with TAA holds promise for advancing precision of treating this condition and our depth of its understanding, contributing to more comprehensive and insightful patient care.

Publisher

MDPI AG

Reference46 articles.

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3