Author:
Reda Ibrahim,AbdelMessih Raouf N.,Steit Mohamed,Mina Ehab M.
Abstract
This study seeks to evaluate thermal comfort in naturally ventilated classrooms to draw sustainable solutions that reduce the dramatic energy consumed in mechanically ventilated spaces. Passive ventilation scenarios are generated using alternations of openings on the windward and leeward sides to evaluate their effects on thermal comfort. Twenty-eight experiments were carried in Bahrain during winter inside an exposed classroom, the experiments were grouped into five scenarios namely: “single-inlet single-outlet” SISO, “single-inlet double-outlet” SIDO, “double-inlet single-outlet” DISO, “double-inlet double-outlet” DIDO and “single-side ventilation” SSV. The findings indicate that single-side ventilation did not offer comfort except at high airspeed, while comfort is attained by using cross-ventilation at ambient temperature between 21.8–26.8 °C. The temperature difference between monitored locations and the inlet is inversely proportional to the number of air changes per hour. The DISO scenario accomplishes the lowest temperature difference. Using cross-ventilation instead of single-side ventilation reduces the temperature differences between 0.5–2.5 °C and increases airspeed up to three folds. According to the measured findings, the DISO cross-ventilation scenario is a valid sustainable solution adaptable to climatic variation locally and beyond with zero-energy consumption and zero emissions.
Subject
Management, Monitoring, Policy and Law,Renewable Energy, Sustainability and the Environment,Geography, Planning and Development
Cited by
4 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献