Comparison of Three Motion Capture-Based Algorithms for Spatiotemporal Gait Characteristics: How Do Algorithms Affect Accuracy and Precision of Clinical Outcomes?

Author:

Caron-Laramée Amélie1,Walha Roua23,Boissy Patrick23ORCID,Gaudreault Nathaly4,Zelovic Nikola1ORCID,Lebel Karina13

Affiliation:

1. Département de Génie Électrique et de Génie Informatique, Faculté de Génie, Université de Sherbrooke, Sherbrooke, QC J1K 2R1, Canada

2. Department of Surgery, Orthopedics Division, Faculty of Medicine and Health Sciences, Université de Sherbrooke, Sherbrooke, QC J1H 5N4, Canada

3. Centre de Recherche sur le Vieillissement, Sherbrooke, QC J1H 4C4, Canada

4. School of Rehabilitation, Faculty of Medicine and Health Sciences, Université de Sherbrooke, Sherbrooke, QC J1H 5N4, Canada

Abstract

Gait assessment is of interest to clinicians and researchers because it provides information about patients’ functional mobility. Optoelectronic camera-based systems with gait event detection algorithms are considered the gold standard for gait assessment. Yet, the choice of the algorithm used to process data and extract the desired parameters from those detected gait events has an impact on the validity and reliability of the gait parameters computed. There are multiple techniques documented in the literature for computing gait events, including the analysis of the minimal position of the heel and toe markers, the computation of the relative distance between sacrum and foot markers, and the assessment of the smallest distance between the heel and toe markers. Validation studies conducted on these algorithms report variations in accuracy. Yet, these studies were conducted in different conditions, at varying gait velocities, and on different populations. The purpose of this study is to compare accuracy, precision, and robustness of three algorithms using motion capture data obtained from 25 healthy persons and 21 psoriatic arthritic patients walking at three distinct speeds on an instrumented treadmill. Errors in gait events recognition (heel strike—HS and toe-off—TO) and their impact on gait metrics (stance phase and stride length) are reported and compared to ground reaction force events measured with force plates. Over the 9114 collected steps across all walking speeds, more than 99% of gait events were recognized by all algorithms. On average, HS events were detected within 1.2 ms of the reference for two algorithms, while the third one detected HS late, with an average detection error of 40.7 ms. Yet, significant variations in accuracy were noted with gait speed; the performance decreased for all algorithms at slow speed. TO events were identified early by all algorithms, with an average error ranging from 16.0 to 100.0 ms. These gait events errors lead to 2–15% inaccuracies in stance phase assessment, while the impact on stride length remains below 0.3 cm. Overall, the algorithm based on the relative distance between the sacral and foot markers stood out for its accuracy, precision, and robustness at all walking speeds.

Funder

Canada Research Chair

Publisher

MDPI AG

Subject

Electrical and Electronic Engineering,Biochemistry,Instrumentation,Atomic and Molecular Physics, and Optics,Analytical Chemistry

Reference34 articles.

1. Mobility, functional ability and health-related quality of life among people of 60 years or older;Borglin;Aging Clin. Exp. Res.,2010

2. The Timed “Up & Go”: A Test of Basic Functional Mobility for Frail Elderly Persons;Podsiadlo;J. Am. Geriatr. Soc.,1991

3. Predicting the Probability for Falls in Community-Dwelling Older Adults Using the Timed Up & Go Test;Brauer;Phys. Ther.,2000

4. Predicting falls in individuals with Parkinson disease: A reconsideration of clinical balance measures;Dibble;J. Neurol. Phys. Ther.,2006

5. Rehabilitation Institute of Chicago (2022, July 07). Rehabilitation Measures Database: Timed Up and Go. Available online: http://www.rehabmeasures.org/Lists/RehabMeasures/DispForm.aspx?ID=903.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3