Non-uniformity in the response of spectral image elements is an inevitable phenomenon in hyperspectral imaging, which mainly manifests itself as the presence of band noise in the acquired hyperspectral data. This problem is prominent in the infrared band owing to the detector material, operating environment, and other factors. Non-uniformity is an important factor that can affect the quality of the hyperspectral data, which has a serious impact on both data analysis and applications and requires corrections via technical means wherever possible. This paper proposes a novel target-based non-uniformity self-correction method for infrared push-broom hyperspectral images. The Mars Mineralogical Spectrometer (MMS) onboard the Tianwen-1 orbiter was used as the research and application object. The model is constructed and applied to the target scene characteristics and detection patterns of Mars remote sensing exploration, which are combined with the causes of noise generation in the infrared spectral image bands. The design of the MMS dual-channel Visible-Near-Infrared (V-NIR) and Near-Mid-Infrared (N-MIR) co-field of view co-target detection and laboratory calibration data for the V-NIR spectral band can achieve non-uniformity corrections (NUCs). Therefore, for the MMS in-orbit Mars exploration mission, the method selected spectral data (920–1055 nm) characterized by a reduced atmospheric influence to iteratively obtain the homogeneous region, which was used to calculate the non-uniformity correction factor for the N-MIR spectral band. This method was compared, validated, and evaluated with other conventional methods using both laboratory and in-orbit hyperspectral data. The results showed that the experimental data corrections were comparable to laboratory calibrations, with a maximum relative deviation of <2.6%. These results prove that our method not only provides an excellent non-uniformity correction, but also ensures spectral fidelity. It can thus be used as a non-uniformity correction process for the MMS and similar hyperspectral imagers.

Funder

Zhiping He

Publisher

MDPI AG

Subject

General Earth and Planetary Sciences

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3