An In Vitro Study of the Reproducibility of the Drilling Access of Digitalized Surgical Guides Generated via Three Different Implant Planning Software Programs

Author:

Visuttiwattanakorn Surakit,Phatthanagowit Bongkoch

Abstract

Several implant planning software programs are widely use in implant treatments, but there has been no evidence of how different software programs affect the accuracy of static surgical guides used for implant placement. Thus, in this in vitro study, we aimed to compare the accuracy of static surgical guides that were prefabricated from three different software programs, including Implant Studio (Program A) (3Shape®, Copenhagen, Denmark), coDiagnostiX® (Program B) (Straumann®, Basal, Switzerland), and Blue Sky Plan (Program C) (Blue Sky Bio®, LLC, Libertyville, IL, USA). A total of 90 drillable polyurethane models were used as samples in this in vitro study; 30 study models were used to plan the same implant positions and design the surgical guides by each software program (n = 30) and then 90 implants were placed in the models using the surgical guides. The outcomes of the surgical guide accuracy were autonomically measured by the evaluation tool in the coDiagnostiX® (Straumann®, Basal, Switzerland) software program. The deviations between the planned and placed implants were automatically evaluated as three-dimensional and angular deviations. The mean three-dimensional implant position deviations from the implant platform of Program A, Program B, and Program C were 0.55 ± 0.25 mm, 0.52 ± 0.31 mm, and 0.56 ± 0.22 mm, respectively. The mean three-dimensional implant position deviations from the implant apex of Program A, Program B, and Program C were 0.72 ± 0.37 mm, 0.73 ± 0.4 mm, and 0.9 ± 0.46 mm, respectively. The mean depth deviations of Program A, Program B, and Program C were 0.19 ± 0.13 mm, 0.31 ± 0.32 mm, and 0.31 ± 0.22 mm, respectively. The mean angulation deviations of Program A, Program B, and Program C were 1.72 ± 0.88 degrees, 2.05 ± 1.24 degrees, and 2.74 ± 1.81 degrees, respectively. The results indicated that there were no significant differences among the three-dimensional positions at the implant platform, the three-dimensional positions at the implant apex, and the depth deviations between all three groups. However, it was found that there was a significant difference in the angular deviation of the implant position between the three groups (p = 0.02). The mean angular deviation of Program C was significantly greater than the Program A group (p = 0.001). In terms of the deviation directions of the implant platform and implant apex for the three groups, most of the deviations of a larger magnitude were toward the mesio-buccal direction. No matter which program was used to plan the implant position, deviations between the placed implant position and the planned position still occurred. Therefore, when planning implant positions with any implant planning software program, one must take into account an implant position deviation.

Publisher

MDPI AG

Subject

Fluid Flow and Transfer Processes,Computer Science Applications,Process Chemistry and Technology,General Engineering,Instrumentation,General Materials Science

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3