Human Urinary Volatilome Analysis in Renal Cancer by Electronic Nose

Author:

Costantini Manuela1ORCID,Filianoti Alessio12ORCID,Anceschi Umberto1,Bove Alfredo Maria1ORCID,Brassetti Aldo1,Ferriero Mariaconsiglia1,Mastroianni Riccardo1,Misuraca Leonardo1,Tuderti Gabriele1ORCID,Ciliberto Gennaro3,Simone Giuseppe1ORCID,Torregiani Giulia4ORCID

Affiliation:

1. Department of Urology, IRCCS—Regina Elena National Cancer Institute, 00144 Rome, Italy

2. Department of Urology, San Filippo Neri Hospital, 00135 Rome, Italy

3. Scientific Direction, IRCCS—Regina Elena National Cancer Institute, 00144 Rome, Italy

4. Department of Anesthesiology and Intensive Care Unit, IRCCS—Regina Elena National Cancer Institute, 00144 Rome, Italy

Abstract

Currently, in clinical practice there are still no useful markers available that are able to diagnose renal cancer in the early stages in the context of population screening. This translates into very high costs for healthcare systems around the world. Analysing urine using an electronic nose (EN) provides volatile organic compounds that can be easily used in the diagnosis of urological diseases. Although no convincing results have been published, some previous studies suggest that dogs trained to sniff urine can recognize different types of tumours (bladder, lung, breast cancer) with different success rates. We therefore hypothesized that urinary volatilome profiling may be able to distinguish patients with renal cancer from healthy controls. A total of 252 individuals, 110 renal patients and 142 healthy controls, were enrolled in this pilot monocentric study. For each participant, we collected, stabilized (at 37 °C) and analysed urine samples using a commercially available electronic nose (Cyranose 320®). Principal component (PCA) analyses, discriminant analysis (CDA) and ROC curves were performed to provide a complete statistical analysis of the sensor responses. The best discriminating principal component groups were identified with univariable ANOVA analysis. The study correctly identified 79/110 patients and 127/142 healthy controls, respectively (specificity 89.4%, sensitivity 71.8%, positive predictive value 84.04%, negative predictive value 80.37%). In order to test the study efficacy, the Cross Validated Accuracy was calculated (CVA 81.7%, p < 0.001). At ROC analysis, the area under the curve was 0.85. The results suggest that urine volatilome profiling by e-Nose seems a promising, accurate and non-invasive diagnostic tool in discriminating patients from controls. The low costs and ease of execution make this test useful in clinical practice.

Funder

Scientific Direction of IRCCS

Publisher

MDPI AG

Subject

Clinical Biochemistry,General Medicine,Analytical Chemistry,Biotechnology,Instrumentation,Biomedical Engineering,Engineering (miscellaneous)

Cited by 5 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3