Short- to Mid-Term Clinical and Radiological Results of Selective Laser Melting Highly Porous Titanium Cup in Primary Total Hip Arthroplasty

Author:

Familiari Filippo12ORCID,Barone Alessandro1,De Gori Marco3ORCID,Banci Lorenzo4ORCID,Palco Michelangelo5ORCID,Simonetta Roberto5,Gasparini Giorgio12ORCID,Mercurio Michele12ORCID,Calafiore Giuseppe67

Affiliation:

1. Department of Orthopaedic and Trauma Surgery, Magna Graecia University, 88100 Catanzaro, Italy

2. Research Center on Musculoskeletal Health, MusculoSkeletalHealth@UMG, Magna Graecia University, 88100 Catanzaro, Italy

3. Ospedale Civile di Soverato, 88068 Soverato, Italy

4. Clinical Department, Permedica Orthopaedics, 23807 Merate, Italy

5. Division of Orthopaedic and Trauma Surgery, Villa del Sole Clinic, 88100 Catanzaro, Italy

6. Clinica Città di Parma, 43123 Parma, Italy

7. IRCSS Humanitas Research Hospital, 20089 Rozzano, Italy

Abstract

(1) Background: The aim of this study was to evaluate short- to mid-term clinical and radiological results in patients undergoing primary total hip arthroplasty (THA) with the use of a Selective Laser Melting 3D-printed highly porous titanium acetabular cup (Jump System Traser®, Permedica Orthopaedics). (2) Methods: We conducted a retrospective study and collected prospective data on 125 consecutive patients who underwent primary THA with the use of highly porous titanium cup. Each patient was evaluated preoperatively and postoperatively with a clinical and radiological assessment. (3) Results: The final cohort consisted of 104 patients evaluated after a correct value of 52 (38–74) months. The median Harris Hip Score (HHS) significantly improved from 63.7 (16–95.8) preoperatively to 94.8 (38.2–95.8) postoperatively (p < 0.001), with higher improvement associated with higher age at surgery (β = 0.22, p = 0.025). On postoperative radiographs, the average acetabular cup inclination and anteversion were 46° (30°–57°) and 15° (1°–32°), respectively. All cups radiographically showed signs of osseointegration with no radiolucency observed, or component loosening. (4) Conclusions: The use of this highly porous acetabular cup in primary THA achieved excellent clinical, functional, and radiological results at mid-term follow-up. A better clinical recovery can be expected in older patients. The radiological evaluation showed excellent osseointegration of the cup with complete absence of periprosthetic radiolucent lines.

Funder

Permedica Orthopaedics

Publisher

MDPI AG

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3