The Wearable Cardioverter-Defibrillator: Experience in 153 Patients and a Long-Term Follow-Up

Author:

Rosenkaimer Stephanie L.,El-Battrawy IbrahimORCID,Dreher Tobias C.,Gerhards Stefan,Röger Susanne,Kuschyk Jürgen,Borggrefe Martin,Akin Ibrahim

Abstract

Background: The wearable cardioverter-defibrillator (WCD) is available for patients at high risk for sudden cardiac death (SCD) when immediate implantable cardioverter-defibrillator (ICD) implantation is not possible or indicated. Patient selection remains challenging especially in primary prevention. Long-term data on these patients is still lacking. Methods: 153 patients were included in this study. They were prescribed the WCD between April 2012 and March 2019 at the University Medical Center, Mannheim, Germany. The mean follow-up period was 36.2 ± 15.6 months. Outcome data, including all-cause mortality, were analyzed by disease etiology and ICD implantation following WCD use. Results: We analyzed 56 patients with ischemic cardiomyopathy, 70 patients with non-ischemic cardiomyopathy, 16 patients with prior need for ICD/CRT-D (device for cardiac resynchronization therapy with defibrillator) explanation, 8 patients with acute myocarditis and 3 patients with congenital diseases. 58% of the patients did not need ICD/CRT-D implantation after WCD use. 4% of all patients suffered from appropriate WCD shocks. 2 of these patients (33%) experienced appropriate ICD shocks after implantation due to ventricular tachyarrhythmias. Long-term follow-up shows a good overall survival. All-cause mortality was 10%. There was no significant difference between patients with or without subsequent ICD implantation (p = 0.48). Patients with ischemic cardiomyopathy numerically showed a higher long-term mortality than patients with non-ischemic cardiomyopathy (14% vs. 6%, p = 0.13) and received significantly more ICD shocks after implantation (10% of ischemic cardiomyopathy (ICM) patients versus 3% of non-ischemic cardiomyopathy (NICM) patients, p = 0.04). All patients with ventricular tachyarrhythmias during WCD use or after ICD implantation survived the follow-up period. Conclusion: Following WCD use, ICD implantation could be avoided in 58% of patients. Long-term follow-up shows good overall survival. The majority of all patients did not suffer from WCD shocks nor did receive ICD shocks after subsequent implantation. Patient selection regarding predictive conditions on long-term risk of ventricular tachyarrhythmias needs further risk stratification.

Publisher

MDPI AG

Subject

General Medicine

Reference27 articles.

1. European Society of Cardiology Guidelines for the management of patients with ventricular arrhythmias and the prevention of sudden cardiac death summarized by co-chairs;Priori;Eur. Heart J.,2015

2. 2016 ESC Guidelines for the Diagnosis and Treatment of Acute and Chronic Heart Failure;Ponikowski;Rev. Esp. Cardiol. (Engl. Ed.),2016

3. Sudden Death After Myocardial Infarction

4. The relationships of left ventricular ejection fraction, end-systolic volume index and infarct size to six-month mortality after hospital discharge following myocardial infarction treated by thrombolysis

5. Sudden Death in Patients with Myocardial Infarction and Left Ventricular Dysfunction, Heart Failure, or Both

Cited by 18 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3