Handclap is a convenient and useful acoustic source. This study aimed to explore its optimal application and limitations for acoustic measurements as well for other possible utilizations. For this purpose, the following steps were performed: investigation of the optimal hand configuration for acoustic measurements and measurements at different microphone source distances and at different spaces and positions. All measurements were performed with a handclap and a dodecahedron speaker for comparison. The results indicate that the optimal hand configuration (among 11) is with the hands cupped and held at an angle due to the superior low frequency spectrum. This configuration produced usable acoustic parameter measurements in the low frequency range in common room background levels unlike other configurations. The reverberation time was measured across different spaces and positions with a deviation less than three and just a noticeable difference of the signal-to-noise ratio within or near the ISO 3382-1 limits for each corresponding octave band. Other acoustic parameters (i.e., early decay time, clarity) were measured with greater deviations for reasons discussed in the text. Finally, practical steps for measurements with a handclap as an acoustic source are suggested.