Abstract

Microparameter calibration is an important problem that must be solved in the discrete element method. The Gaussian process (GP) response surface methodology was proposed to calibrate the microparameters based on the Bayesian principle in machine-learning methods, which addresses the problems of uncertainty, blindness, and repeatability in microparameter calibration methods. Using the particle flow code (PFC) as an example, the effects of the microparameters on the macroparameters were evaluated using the control-variable method, and the range of the microparameters was determined based on the macroparameters. The uniform design (UD) method and numerical calculation were used to obtain training samples, and a GP response surface methodology suitable for multifactor, multilevel, and nonlinear processes was used to establish the response surface relationships for macro–micro parameters of rock-like materials in discrete element method. According to the macroparameters obtained from the uniaxial experiments conducted on rock specimens, the microparameters were calibrated using the GP response surfaces. Numerical calculations of uniaxial compression and Brazilian splitting were performed using microparameters, and the results were compared with laboratory experiments for verification. The results showed that the relative errors of the GP response surface and laboratory test values were 5.3% for the modulus of elasticity, −7.8% for compressive strength, and −2.6% for tensile strength. The nonlinear GP response surface considered the characteristics of multiple interacting factors, and the established nonlinear response surface relationship between the microparameters and macroparameters can be used for the calibration of microparameters. The accuracy of the microparameters was verified according to the stress–strain curve and failure morphology of the rock specimens. The method of using the GP response surface to establish the macro–micro parameter relationship in the discrete element method can also be extended to other numerical simulation methods and can provide a basis for accurately analysing the microdamage mechanism of rock materials under complex loading conditions.

Funder

Foshan Science and Technology Innovation Special Fund Funding Project

National Key Research and Development Program of China

Publisher

MDPI AG

Subject

Process Chemistry and Technology,Chemical Engineering (miscellaneous),Bioengineering

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3