Experimental Determination of Lamb-Wave Attenuation Coefficients

Author:

Ono KanjiORCID

Abstract

This work determined the attenuation coefficients of Lamb waves of ten engineering materials and compared the results with calculated Lamb-wave attenuation coefficients, α–S and α–A. The Disperse program and a parametric method based on Disperse results were used for calculations. Bulk-wave attenuation coefficients, αL and αT, were required as input parameters to the Disperse calculations. The calculated α–S and α–A values were found to be dominated by the αT contribution. Often α–Ao coincided with αT. The values of αL and αT were previously obtained or newly measured. Attenuation measurement relied on Lamb-wave generation by pulsed excitation of ultrasonic transducers and on surface-displacement detection with point contact receivers. The frequency used ranged from 10 kHz to 1 MHz. A total of 14 sheet and plate samples were evaluated. Sample materials ranged from steel, Al, and silicate glass with low attenuation to polymers and a fiber composite with much higher attenuation. Experimentally obtained Lamb-wave attenuation coefficients, α–S and α–A, for symmetric and asymmetric modes, were mostly for the zeroth mode. Plots of α–So and α–Ao values against frequency were found to coincide reasonably well to theoretically calculated curves. This study confirmed that the Disperse program predicts Lamb-wave attenuation coefficients for elastically isotropic materials within the limitation of the contact ultrasonic techniques used. Further refinements in experimental methods are needed, as large deviations often occurred, especially at low and high frequencies. Methods of refinement are suggested. Displacement measurements were quantified using Rayleigh wave calibration. For signals below 300 kHz, 1-mV receiver output corresponded to 1-pm displacement. Peak displacements after 200-mm propagation were found to range from 10 pm to 1.5 nm. With the use of signal averaging, the point-contact sensor was capable of detecting 1-pm displacement with 40 dB signal-to-noise ratio and had equivalent noise of 4.3 fm/√Hz. Approximate expressions for α–So and α–Ao were obtained, and an empirical correlation was found between bulk-wave attenuation coefficients, i.e., αT = 2.79 αL, for over 150 materials.

Publisher

MDPI AG

Subject

Fluid Flow and Transfer Processes,Computer Science Applications,Process Chemistry and Technology,General Engineering,Instrumentation,General Materials Science

Reference52 articles.

1. Nondestructive Testing Handbook,2007

2. Nondestructive Testing Handbook,2005

3. Encyclopedia of Structural Health Monitoring,2009

4. Guided waves' dispersion curves in anisotropic viscoelastic single- and multi-layered media

5. Strategies for guided-wave structural health monitoring

Cited by 7 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3