Impacts of Harmonic Voltage Distortions on the Dynamic Behavior and the PRPD Patterns of Partial Discharges in an Air Cavity Inside a Solid Dielectric Material

Author:

Machado Gustavo de OliveiraORCID,Gomes Luciano CoutinhoORCID,da Silveira Augusto Wohlgemuth Fleury VelosoORCID,Tavares Carlos Eduardo,de Andrade Darizon Alves

Abstract

The monitoring of partial discharges (PDs) is one of the main methods used worldwide for evaluation and diagnosis of the insulation conditions in equipment powered by medium and high voltages. The occurrence of PDs is usually an indication of the appearance of insulation defects, which over time can compromise the dielectric withstand of the material used, increasing the probability of complete breakdown. In general, laboratory tests for detecting and registering PDs are carried out using purely sinusoidal voltages. However, it is very common for an electrical asset to be subjected at some point in its operating life to voltages distorted by harmonic components. Some studies reported in the literature reveal that harmonic distortions can affect the PDs’ characteristics, nevertheless, the effects of individual harmonic components on PDs still need to be analyzed. In this context, this paper proposes to evaluate the impacts of harmonic voltage distortions on the dynamic behavior and the phase-resolved partial discharge (PRPD) patterns of PDs in an air cavity within a solid dielectric material. For this, a simulation model was implemented, which was used to analyze the effects of applying distorted voltages composed of different harmonic orders (third, fifth, and seventh) and distinct levels of distortion (1%, 3%, 5%, 10%, 15%, and 20%). In addition, the influence of the third harmonic phase angle on PDs is also analyzed. The results extracted from the simulations revealed that the harmonic distortions caused changes in the numbers of PDs per cycle, in the mean apparent charges of the PDs per cycle, and in the PRPD patterns’ characteristics. These changes were very significant for higher distortion levels, which in practice may impair the interpretation of PD measurement records for the diagnosis of the condition of the insulation system.

Publisher

MDPI AG

Subject

Energy (miscellaneous),Energy Engineering and Power Technology,Renewable Energy, Sustainability and the Environment,Electrical and Electronic Engineering,Control and Optimization,Engineering (miscellaneous)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3