Author:
Ishino Yuji,Mizuno Takeshi,Takasaki Masaya,Yamaguchi Daisuke
Abstract
The stabilization of a magnetic suspension system is achieved by using a low-pass filter (LPF) with a nonlinear integrator without any other element. A proportional-derivative (PD) control is commonly used as the simplest method of stabilizing a magnetic suspension system. Meanwhile, a first-order reset element (FORE) was applied to improve transient characteristics. The original FORE was a first-order LPF with a nonlinear reset integrator element. A magnetic suspension system cannot be stabilized by a linear LPF, nor the original FORE. In this work, the reset conditions of the FORE were modified for magnetic suspension. This modified FORE succeeded in stabilizing a magnetic suspension system. The efficacy of the modified FORE was demonstrated by simulations and experiments. A single degree of freedom magnetic suspension system was used in the experiment.
Subject
Control and Optimization,Control and Systems Engineering
Cited by
3 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献