Abstract

Accurate and reliable laboratory results are an extremely important and integral part of conducting scientific research. Many factors influence the results obtained, including the type of determination method, accuracy and precision of measurements, and laboratory equipment used for the tests. This paper presents the results of measurements of heavy metal concentration in soil using two methods for adding soil components into solution and different laboratory methods and types of measuring equipment. The first method used was hot digestion of soil samples with a mixture of concentrated HNO3 and HClO4, after prior ashing of organic matter (IUNG method). The second method was a two-stage decomposition, where soil samples were hot digested, initially with oxidizing acid (HNO3) and subsequently with non-oxidizing acid (HF) (two-stage decomposition). The concentrations of selected heavy metals (Cr, Cu, Fe, Mn, Ni, Pb and Zn) were determined in solutions obtained by both digestion methods. The solutions obtained from soil decomposition were determined twice using atomic absorption spectrometry (AAS) and inductively coupled plasma mass spectrometry (ICP MS) methods in different laboratories using different types of spectrometers. In most cases, the measured concentrations of heavy metals are the highest for the two-stage solution samples and the measurements of their concentrations carried out using ICP. The exceptions are the measurements of Cu and Ni concentrations. In the case of Cu, lack of significant differentiation in concentrations of this metal may result from different forms of occurrence of Cu in soil than in the case of other metals. For Ni, however, a reversal of the trends seen for the other metals is observed and the type of spectrometer used for measurements is important. There may be an interference of the spectrometric spectrum of Ni with the spectra of the other determined metals. However, this is not clear at the present stage of the study. In conclusion, the results of this study indicate that the choice of soil sample preparation and the type of spectrometer used for measurements can, in many cases, determine the value of laboratory results, even if it is in an expected range of standard material. Research of published papers proved that most of them show only results based on one selected course of methodology without comparison with others. The novelty of the paper is the comparison of the measurements of heavy metal concentration in soil using two methods for adding soil components into solution and different laboratory methods and types of measuring equipment. Additionally, the article includes a discussion of the importance of methodology. We believe that the conclusions may help to better understand how sample preparation and measurement methods applied may influence the results obtained.

Funder

Scientific Research Committee

Publisher

MDPI AG

Subject

Fluid Flow and Transfer Processes,Computer Science Applications,Process Chemistry and Technology,General Engineering,Instrumentation,General Materials Science

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3