The Cyclic Fatigue Resistance of Different Lengths of CM Gold Wire and CM Blue Wire NiTi Alloy Endodontic Rotary Files: An In Vitro Study

Author:

Faus-Matoses Vicente1ORCID,Faus-Llácer Vicente1ORCID,Ruiz-Sánchez Celia1,Prats Gallego Sofía1,Zubizarreta-Macho Álvaro23,Solano-Mendoza Beatriz4ORCID,Biedma Benjamín Martín5ORCID,Faus-Matoses Ignacio1

Affiliation:

1. Department of Stomatology, Faculty of Medicine and Dentistry, University of Valencia, Avda. Blasco Ibáñez, 46010 Valencia, Spain

2. Department of Implant Surgery, Faculty of Health Sciences, Alfonso X El Sabio University, 28691 Madrid, Spain

3. Department of Surgery, University of Salamanca, 37008 Salamanca, Spain

4. Department of Orthodontics, University of Sevilla, 41009 Sevilla, Spain

5. Department of Surgery and Medical-Surgical Specialties, School of Medicine and Dentistry, Universidad de Santiago de Compostela, 15705 La Coruña, Spain

Abstract

Background: The objective of the present study was to measure and compare how the length of CM Gold Wire and CM Blue Wire NiTi alloy endodontic rotary files impacts their resistance to cyclic fatigue. Methods: A total of 40 sterile endodontic rotary files were chosen and allocated to the following study groups: (A) 25.06 CM Gold wire NiTi alloy endodontic rotary files, 31 mm in length (n = 10); (B) 25.06 CM Gold wire NiTi alloy endodontic rotary files, 25 mm in length (n = 10); (C) 25.06 CM Gold wire NiTi alloy endodontic rotary files, 21 mm in length (n = 10); and (D) 25.06 CM Blue wire NiTi alloy endodontic rotary files, 17 mm in length (n = 10). A specialized device was designed using artificial root canal systems made from stainless steel for the dynamic cyclic fatigue tests, with an apical diameter of 250 µm, curvature angle of 60°, radius of curvature of 5 mm, lengths of 31, 25, 21, and 17 mm, and a 6% taper. An individual operator determined failure of the endodontic rotary instrument through direct observation and the tests were filmed so as to precisely measure the exact time to failure. The results were analyzed using ANOVA and Weibull statistical analysis. Results: The results found statistically significant differences across all study groups (p < 0.05). Conclusions: Rotary file length is inversely proportional to the cyclic fatigue resistance of the 25.06 CM Gold wire NiTi alloy at 31 mm, 25 mm, and 21 mm in length and of the 25.06 CM Blue wire NiTi alloy 17 mm length endodontic rotary files, with a greater length contributing to lower resistance to cyclic fatigue.

Publisher

MDPI AG

Subject

Fluid Flow and Transfer Processes,Computer Science Applications,Process Chemistry and Technology,General Engineering,Instrumentation,General Materials Science

Reference33 articles.

1. Comparison between Single-file Rotary Systems: Part 2-The Effect of Length of the Instrument Subjected to Cyclic Loading on Cyclic Fatigue Resistance;Azim;J. Endod.,2018

2. Manual vs. rotary instrumentation in endodontic treatment of permanent teeth: A systematic review and meta-analysis;Rios;Am. J. Dent.,2019

3. Cyclic fatigue resistance of reduced-taper nickel-titanium (NiTi) instruments in doubled-curved (S-shaped) canals at body temperature;Uslu;J. Dent. Res. Dent. Clin. Dent. Prospect.,2020

4. Mechanical root canal preparation with NiTi rotary instruments: Rationale, performance and safety. Status report for the American Journal of Dentistry;Bergmans;Am. J. Dent.,2001

5. Instrument fracture: Mechanisms, removal of fragments, and clinical outcomes;Cheung;Endod. Top.,2009

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献