Optimization of the Position and Stiffness of Passive Walking Assistance Devices

Author:

Guzelbulut Cem1ORCID,Shimono Satoshi23,Suzuki Katsuyuki1

Affiliation:

1. Department of Systems Innovation, School of Engineering, The University of Tokyo, Tokyo 113-8656, Japan

2. Mitsubishi Chemical Group Corporation, Tokyo 100-8251, Japan

3. The Global KAITEKI Center, Arizona State University, Tempe, AZ 85281, USA

Abstract

Walking is a fundamental movement in daily life; however, many factors affect walking that may reduce the mobility of the people. Walking assistance devices can help with gaining mobility back for people who suffer from walking problems. In the present study, a computational method to determine the location and stiffness of the assistive walking systems was developed. The human walking model was created by using nine rigid bodies and eight revolute joints connecting them in the sagittal plane. The walking assistance system was considered as a tension spring with both ends attached to the human walking model. A coordinate system was defined along the distal–proximal direction of the human body. The position of the walking assistance system was determined by using four design variables, and the optimal position of the assistive walking system to reduce the total positive joint energy was found around the hip joint at a walking speed of 1.3 m/s. Hip joint moment and power were significantly affected by the walking assistance system, and the total positive joint energy was reduced by 8.8%. Because walking speed significantly affects walking kinematics and kinetics, the effect of walking speed on the optimal walking assistance device was investigated. The position of the device was kept the same, and the optimal stiffness and free length of the spring were found at different walking speeds. Two different cases were considered: a speed-specific design in which stiffness characteristics were separately optimized for each speed and a general design in which stiffness characteristics were optimized by considering all walking speeds. It was found that, in both cases, hip joint moment and power significantly reduced, and the speed-specific design produced a slightly larger reduction in total joint energy. The performance of the walking assistance systems in both cases were found to be higher at faster walking speeds.

Publisher

MDPI AG

Subject

Fluid Flow and Transfer Processes,Computer Science Applications,Process Chemistry and Technology,General Engineering,Instrumentation,General Materials Science

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3