Digital Occlusion Analysis after Orthodontic Treatment: Capabilities of the Intraoral Scanner and T-Scan Novus System

Author:

Shopova Dobromira1ORCID,Bakova Desislava2ORCID,Yordanova Svetlana3,Yordanova Miroslava3,Uzunov Todor4

Affiliation:

1. Department of Prosthetic Dentistry, Faculty of Dental Medicine, Medical University of Plovdiv, 4000 Plovdiv, Bulgaria

2. Department of Healthcare Management, Faculty of Public Health, Medical University of Plovdiv, 4000 Plovdiv, Bulgaria

3. Department of Orthodontics, Faculty of Dental Medicine, Medical University of Plovdiv, 4000 Plovdiv, Bulgaria

4. Department of Prosthetic Dentistry, Faculty of Dental Medicine, Medical University of Sofia, 1431 Sofia, Bulgaria

Abstract

Digital technology is becoming increasingly popular in dentistry. The aim of this article is to demonstrate and compare the capabilities of two different digital approaches, namely, intraoral scanning and digital examination of occlusion, in the final analysis of occlusion after orthodontic treatment. The capabilities and limitations of both systems are emphasized to help clinicians determine which system to use in specific cases. Materials and methods: The study included 32 patients (15 males and 17 females) in the retention phase after orthodontic treatment. Patients were aged 15 to 28 years with a mean age of 18.62 years (±4.17), and 62.2% were aged under 18 years. At the beginning of the orthodontic treatment, 18 patients had Angle Class I and 14 had Angle Class II. Overall, 18 patients were treated without extractions and 14 with extractions, while 12 had impacted teeth. All patients wore an Essix retainer in the upper jaw and a fixed canine-to-canine retainer in the lower jaw. Intraoral scanning was performed using Trios color (3Shape, Copenhagen, Denmark, 2014), and digital occlusion imaging was performed using T-Scan Novus (Tekscan, Norwood, MA, USA, 2018). SPSS 23.0 was used to perform descriptive statistical analysis. Result and Conclusion: With the 3Shape system, the contacts are marked based on the proximity between dentitions. The T-Scan system measures the strength of the contacts, regardless of their area. Despite its many advantages, intraoral scanning is not a reliable method for recording occlusions. The results obtained are not incorrect, but they include limited parameters for analysis. The T-Scan system provides comprehensive results and allows analysis and treatment of occlusal dysfunctions. The T-Scan system can provide information on the first contact, strength of the contacts, contact distribution on each tooth, sequence of contacts, maximum bite force and maximum intercuspation, path of the lower jaw movement, and occlusion and disocclusion times as well as record videos with active sequences and distributions of the contacts. There is a good collaboration between intraoral scanning and digital occlusion determination.

Funder

Medical University of Plovdiv

Publisher

MDPI AG

Subject

Fluid Flow and Transfer Processes,Computer Science Applications,Process Chemistry and Technology,General Engineering,Instrumentation,General Materials Science

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3